ProNet
Series
AC Servo User's Manual
- 103 -
4.6.7 Reference Pulse Inhibit Function (INHIBIT)
(1)Description
This function inhibits the servo drive from counting input pulses during position control.
The servomotor remains locked (clamped) while pulses are inhibited.
Error Counter
+
-
Feedback pulse
OFF
ON
Pn005.1
Pn005=H.
□□
1
□
Pn005=H.
□□B□
Reference pulse
/P-CON
/P-CON
Servodrive
(2)Setting Parameters
Parameter Meaning
Pn005
H.□□B□
Control mode selection
:
position control(pulse train reference)
⇔
INHIBIT
■
Inhibit(INHIBIT) switching condition
·
/P-CON signal ON (low level)
(3)Setting Input Signals
Type
Signal
Name
Connector Pin
Number
Setting Meaning
Input /P-CON
CN1-15
ON(low level)
Turns the INHIBIT function ON.
(Inhibit the servo drive from counting reference
pulses)
OFF(high level)
Turns the INHIBIT function OFF.
(Counters reference pulses.)
Содержание pronet series
Страница 1: ...ProNet SeriesAC Servo User s Manual Version V2 10...
Страница 13: ...ProNet Series ACServoUser sManual 11 ProNet 1AD 1ED 2BD ProNet 02B ProNet 04B ProNet 08B...
Страница 21: ...ProNet Series ACServoUser sManual 19 ProNet 1AD 1ED 2BD ProNet 02B ProNet E 02B...
Страница 22: ...ProNet Series ACServoUser sManual 20 ProNet 04B ProNet E 04B ProNet 08B ProNet E 08B...
Страница 163: ...ProNet Series ACServoUser sManual 161 ProNet 75D 1AD 1ED 2BD Unit mm Air Flow Air Flow Air Flow...
Страница 193: ......