Parameter
No.
Name Unit
Setting
Range
Factory
Setting
Setting
Invalidation
Pn514
Input port filter
0.2ms 0~1000 1 Immediately
Pn515
Alarm port filter
0.2ms
0~3
1
Immediately
Pn516
Input port signal inversion
—
0~1111
0
Immediately
Pn517
Input port signal inversion
—
0~1111
0
Immediately
Pn518
Dynamic brake time
0.5ms
50~2000 125 Immediately
Pn519
Serial encoder error time
0.1ms
0~10000
3
Immediately
Pn520
Position complete time
0.1ms
0~60000
500
Immediately
Pn521
If connect externally regenerative resistor
0
:
connect externally regenerative resistor
between B1 and B2
1
:
dose not connect externally
regenerative resistor, relay on internal
capacitance
(
This parameter is in effect only on
ProNet-02/04
/
ProNet-E-02/04
)
— 0~1 1
Immediately
Pn522
Reserved —
—
—
—
Pn523
Reserved —
—
—
—
Pn524
Reserved
—
—
—
—
Pn525
Overload alarm threshold
%
100~150
100
Immediately
Pn526
Temperature threshold of motor overheat
alarm
(
Only enabled in ProNet–75/1A/1E/2B
)
℃
50~180 110
Immediately
Pn528
Output signal inverse
—
0~1111
0
Immediately
Pn529
Torque detection output signal threshold
value
% 3~300
100
Immediately
Pn530
Torque detection output signal time
ms
1~1000
10
After restart
Pn600
Position pulse in point to point control
10000P
-9999~9999
0
Immediately
Pn601
Position pulse in point to point control
1P
-9999~9999
0
Immediately
……
Pn630
Position pulse in point to point control
1P
-9999~9999
0
Immediately
Pn631
Position pulse in point to point control
1P
-9999~9999
0
Immediately
Pn632
Point to point speed control
rpm
0~3000
500
Immediately
……
Pn647
Point to point speed control
rpm
0~3000
500
Immediately
Pn648
Point to point 1st order filter 0.1ms
0~32767
0
Immediately
……
Pn663
Point to point 1st order filter 0.1ms
0~32767
0
Immediately
Pn664
Stop time
50ms
0~300
10
Immediately
……
Pn679
Stop time
50ms
0~300
10
Immediately
Pn680
Reserved
—
—
—
—
Pn681
Hex
Pn681.0:Single/cyclic, start/reference point
— 0~0x0133
0x0000
Immediately
Содержание pronet series
Страница 1: ...ProNet SeriesAC Servo User s Manual Version V2 10...
Страница 13: ...ProNet Series ACServoUser sManual 11 ProNet 1AD 1ED 2BD ProNet 02B ProNet 04B ProNet 08B...
Страница 21: ...ProNet Series ACServoUser sManual 19 ProNet 1AD 1ED 2BD ProNet 02B ProNet E 02B...
Страница 22: ...ProNet Series ACServoUser sManual 20 ProNet 04B ProNet E 04B ProNet 08B ProNet E 08B...
Страница 163: ...ProNet Series ACServoUser sManual 161 ProNet 75D 1AD 1ED 2BD Unit mm Air Flow Air Flow Air Flow...
Страница 193: ......