4.8.1 Setting Parameters
Parameter Meaning
Pn005
H.□□3□
Control mode selection:
Speed control(contact reference) Speed control(zero reference)
Pn316
Internal set speed 1
Setting Range
Setting Unit
Factory Setting
Setting Validation
-6000~6000
rpm
100
Immediately
Pn317
Internal set speed 2
Setting Range
Setting Unit
Factory Setting
Setting Validation
-6000~6000
rpm
200
Immediately
Pn318
Internal set speed 3
Setting Range
Setting Unit
Factory Setting
Setting Validation
-6000~6000
rpm
300
Immediately
Pn319
Internal set speed 4
Setting Range
Setting Unit
Factory Setting
Setting Validation
-6000~6000
rpm
-100
Immediately
Pn320
Internal set speed 5
Setting Range
Setting Unit
Factory Setting
Setting Validation
-6000~6000
rpm
-200
Immediately
Pn321
Internal set speed 6
Setting Range
Setting Unit
Factory Setting
Setting Validation
-6000~6000
rpm
-300
Immediately
Pn322
Internal set speed 7
Setting Range
Setting Unit
Factory Setting
Setting Validation
-6000~6000
rpm
500
Immediately
(Note):The servomotor’s maximum speed will be used whenever a speed setting for the
Pn316~Pn322
exceeds the
maximum speed.
speed
speed
speed
speed
speed
speed
speed
Содержание pronet series
Страница 1: ...ProNet SeriesAC Servo User s Manual Version V2 10...
Страница 13: ...ProNet Series ACServoUser sManual 11 ProNet 1AD 1ED 2BD ProNet 02B ProNet 04B ProNet 08B...
Страница 21: ...ProNet Series ACServoUser sManual 19 ProNet 1AD 1ED 2BD ProNet 02B ProNet E 02B...
Страница 22: ...ProNet Series ACServoUser sManual 20 ProNet 04B ProNet E 04B ProNet 08B ProNet E 08B...
Страница 163: ...ProNet Series ACServoUser sManual 161 ProNet 75D 1AD 1ED 2BD Unit mm Air Flow Air Flow Air Flow...
Страница 193: ......