ProNet
Series
AC Servo User's Manual
- 96 -
4.6.2 Setting the Clear Signal
(
1
)
Setting the Clear Signal
Type
Sign Name
Connector Pin Numbe
Function
Input
/CLR
1CN-40
error counter clear
When the /CLR signal is set to low level, clear error counter:
·
The error counter inside the servo drive is set to “0”
·
Position loop operation is disabled.
(
2
)
Setting the Clear Signal Mode
In position control mode, pulses will be still presented in the servo drive when servo OFF, thus it should be cleared when
servo drive is turned ON. Setting Pn004 to choose whether clearing the pulses automatically when servo OFF.
Pn004
□□0□
Clear the error pulse when S-OFF, do not when overtravel.
□□1□
Do not clear the error pulse.
□□2□
Clear the error pulse when S-OFF or overtravel (excep for zero clamp)
4.6.3 Setting the Electronic Gear
(
1
)
Electronic Gear
The electronic gear enables the workpiece travel distance per input reference pulse from the host controller to be set to
any value.
One reference pulse from the host controller, i.e., the minimum position data unit, is called a reference unit.
When the Electronic Gear is Not Used
When the Electronic Gear is Used
workpiece
workpiece
No. of encoder
pulses
:
32768
Ball screw pitch
:
6mm
No. of encoder
pulses
:
32768
Ball screw pitch
:
6mm
One revolution is 6mm. Therefore 10÷6
=
1.6666 revolutions.
32768×4 pulses is one revolution.
Therefore, 1.6666×32768×4
=
218445
pulses. 218445 pulses are input as
reference pulses.
The equation must be calculated at the
host controller.
To move a workpiece 10mm :
The reference unit is 1µm. Therefore, to
move the workpiece 10mm (10000µm),
1pulse=1µm, so 10000/1
=
10000 pulses.
Input 10000 pulses per 10mm of
workpiece movement.
To move a workpiece 10mm using
reference units:
Reference unit
:
1µm
Содержание pronet series
Страница 1: ...ProNet SeriesAC Servo User s Manual Version V2 10...
Страница 13: ...ProNet Series ACServoUser sManual 11 ProNet 1AD 1ED 2BD ProNet 02B ProNet 04B ProNet 08B...
Страница 21: ...ProNet Series ACServoUser sManual 19 ProNet 1AD 1ED 2BD ProNet 02B ProNet E 02B...
Страница 22: ...ProNet Series ACServoUser sManual 20 ProNet 04B ProNet E 04B ProNet 08B ProNet E 08B...
Страница 163: ...ProNet Series ACServoUser sManual 161 ProNet 75D 1AD 1ED 2BD Unit mm Air Flow Air Flow Air Flow...
Страница 193: ......