ProNet
Series
AC Servo User's Manual
- 182 -
Parameter
No.
Description
Setting
Validation
Control
Mode
Function and Meaning
4
:
ALMRST
5
:
CLR
6
:
P-CL
7
:
N-CL
8
:
G-SEL
9
:
JDPOS-JOG+
A
:
JDPOS-JOG-
B
:
JDPOS-HALT
C
:
HmRef
D
:
SHOM
E
:
ORG
Pn511
Output signal
allocation
After restart
P
,
S
,
T
Pn511.0 corresponding port CN1_11
,
CN1_12
Pn511.1 corresponding port CN1_05
,
CN1_06
Pn511.2 corresponding port CN1_09
,
CN1_10
Corresponding signal of each data is shown as
follows:
0
:
/COIN/VCMP
1
:
/TGON
2
:
/S-RDY
3
:
/CLT
4
:
/BK
5
:
/PGC
6
:
OT
7
:
/RD
8
:
/HOME
9
:
/TCR
Pn512
Bus control input
node low-bit enabled
Immediately
P
,
S
,
T
Bus communication input port enabled:
[0]
:
Disabled
[1]
:
Enabled
Pn512.0
Æ
CN1_14
Pn512.1
Æ
CN1_15
Pn512.2
Æ
CN1_16
Pn512.3
Æ
CN1_17
Pn513.0
Æ
CN1_39
Pn513.1
Æ
CN1_40
Pn513.2
Æ
CN1_41
Pn513.3
Æ
CN1_42
Pn513
Bus control input
node low-bit enabled
Immediately
P
,
S
,
T
Pn514
Input port filter
Immediately
P
,
S
,
T
It is used to set input port filter time. The signal will be
lagged if the parameter setting is too high.
Pn515
Reserved
—
—
—
Содержание pronet series
Страница 1: ...ProNet SeriesAC Servo User s Manual Version V2 10...
Страница 13: ...ProNet Series ACServoUser sManual 11 ProNet 1AD 1ED 2BD ProNet 02B ProNet 04B ProNet 08B...
Страница 21: ...ProNet Series ACServoUser sManual 19 ProNet 1AD 1ED 2BD ProNet 02B ProNet E 02B...
Страница 22: ...ProNet Series ACServoUser sManual 20 ProNet 04B ProNet E 04B ProNet 08B ProNet E 08B...
Страница 163: ...ProNet Series ACServoUser sManual 161 ProNet 75D 1AD 1ED 2BD Unit mm Air Flow Air Flow Air Flow...
Страница 193: ......