ProNet
Series
AC Servo User's Manual
- 113 -
4.7.4 Limiting Servomotor Speed During Torque Control
During torque control, the servomotor is controlled to output the specified torque, which means that the servomotor speed
is not controlled. Accordingly, when an excessive reference torque is set for the mechanical load torque, it will prevail over
the mechanical load torque and the servomotor speed will greatly increase.
This function serves to limit the servomotor speed during torque control to protect the machine.
Without Speed Limit
With Speed Limit
(1)Speed Limit Enable
Parameter Description
Pn001
b.□□0□
Use the value set in Pn406 as the speed limit
(
Internal speed limit
)
b.□□1□
Use the lower speed between V-REF and Pn406 as an external speed limit
input.(External speed limit)
(2)Speed Limit During Torque Control
Pn406
Speed Limit During Torque Control
Setting Range
Setting Unit
Factory Setting
Setting Validation
0
~
6000
rpm 1500 Immediately
·
Set the servomotor speed limit value during torque control.
·
Pn005=H
.□□
1
□,
Pn406 is motor speed limit value.
·
The servomotor’s maximum speed will be used when the setting in this parameter exceeds the maximum speed of the
servomotor used.
Torque
Содержание pronet series
Страница 1: ...ProNet SeriesAC Servo User s Manual Version V2 10...
Страница 13: ...ProNet Series ACServoUser sManual 11 ProNet 1AD 1ED 2BD ProNet 02B ProNet 04B ProNet 08B...
Страница 21: ...ProNet Series ACServoUser sManual 19 ProNet 1AD 1ED 2BD ProNet 02B ProNet E 02B...
Страница 22: ...ProNet Series ACServoUser sManual 20 ProNet 04B ProNet E 04B ProNet 08B ProNet E 08B...
Страница 163: ...ProNet Series ACServoUser sManual 161 ProNet 75D 1AD 1ED 2BD Unit mm Air Flow Air Flow Air Flow...