Related Parameters
Parameter Meaning
Pn006
H.□0□□
0:Low frequency vibration suppression function disabled
1:Low frequency vibration suppression function enabled
H.□1□□
Pn411
Low frequency vibration frequency
Setting Range
Setting Unit
Factory Setting
Setting Validation
50
~
500
0.1Hz 100 Immediately
Pn412
Low frequency vibration damp
Setting Range
Setting Unit
Factory Setting
Setting Validation
0
~
200
— 25 Immediately
·
Writing the frequency data to parameter Pn411 can adjust Pn411 slightly to obtain the best suppression effect.
·
If the servomotor stopped with continuous vibration, Pn412(Do not change in general) should be increased properly.
·
Parameter Pn411 and Pn412 are enabled when Pn006.2=1 (Setting validation: after restart).
Position
Speed
Position
Speed