ProNet
Series
AC Servo User's Manual
- 144 -
Chapter 6
MODBUS Communication
6.1 RS-485 Communication Wiring
ProNet series servo drives provide the MODBUS communication function with RS-485 interface,
which can be used to easily set parameters or to perform monitoring operations and so on.
The definitions of the servo drive communication connector terminals are as follows.
CN3
:
Terminal No.
Name
Function
1 —
Reserved
2 —
3
485+
RS-485 communication terminal
4 ISO_GND
Isolated ground
5 ISO_GND
6
485-
RS-485 communication terminal
7
CANH
CAN communication terminal
8
CANL
CAN communication terminal
Note: Do not short terminal 1 and 2 of CN3.
CN4
:
Terminal No.
Name
Function
1 —
Reserved
2 —
Reserved
3
485+
RS-485 communication terminal
4 ISO_GND
Isolated ground
5 ISO_GND
6
485-
RS-485 communication terminal
7
CANH
CAN communication terminal
8
CANL
CAN communication terminal
Note
:
1. The length of the cable should be less than 100 meters and in a environment with minimal electrical
disturbance/interference. However, if the transmission speed is above 9600bps, please use the communication cable
within 15 meters to ensure transmission accuracy..
2. A maximum of 31 servo drives can be connected when RS485 is used. Terminating resistances are used at both ends
of the 485 network. If more devices are wanted to connect, use the repeaters to expand.
3. CN3 of servo drive is always used as communication cable input terminal
,
and CN4 is always used as communication
cable output terminal(If still need to connect slave stations
,
the communication cable is connected from CN4 terminal to
the next slave station; if need not, add balance resistor in CN4 terminal.).It is prohibited to connect CN3 of any two servo
Содержание pronet series
Страница 1: ...ProNet SeriesAC Servo User s Manual Version V2 10...
Страница 13: ...ProNet Series ACServoUser sManual 11 ProNet 1AD 1ED 2BD ProNet 02B ProNet 04B ProNet 08B...
Страница 21: ...ProNet Series ACServoUser sManual 19 ProNet 1AD 1ED 2BD ProNet 02B ProNet E 02B...
Страница 22: ...ProNet Series ACServoUser sManual 20 ProNet 04B ProNet E 04B ProNet 08B ProNet E 08B...
Страница 163: ...ProNet Series ACServoUser sManual 161 ProNet 75D 1AD 1ED 2BD Unit mm Air Flow Air Flow Air Flow...
Страница 193: ......