ProNet
Series
AC Servo User's Manual
- 35 -
3.2.4 Interface Circuit
This section shows examples of servo drive I/O signal connection to the host controller.
■
Interface for Analog Reference Input Circuit
Analog signals are either speed or torque reference signals at about 40k
Ω
impedance, and the maximum allowable
voltages for input signals is ±10V.
Reference speed input
Reference torque input
10V
470
Ω(1/2W)min.
1
2
3
2K
Ω
V-REF
GND
About 40K
Ω
0V
Servodrive
■
Interface for sequence input circuit
The sequence input circuit interface connects through a relay or open-collector transistor circuit. Select a low-current relay
otherwise a faulty contact will result.
■
Interface for line driver output circuit
The amount of two-phase (phase A and phase B) pulse output signals (PAO,/PAO,PBO,/PBO) and zero-point pulse
signals (PCO,/PCO) are output via line-driver output circuits. Normally, the servo drive uses this output circuit in speed
control to comprise the position control system at the host controller. Connect the line-driver output circuit through a line
receiver circuit at the host controller.
■
Interface for sequence output circuit
Photocoupler output circuits are used for Servo Alarm (ALM), Servo Ready(S-RDY), and other sequence output signal
circuits. Connect a photocoupler output circuit through a relay circuit.
Содержание pronet series
Страница 1: ...ProNet SeriesAC Servo User s Manual Version V2 10...
Страница 13: ...ProNet Series ACServoUser sManual 11 ProNet 1AD 1ED 2BD ProNet 02B ProNet 04B ProNet 08B...
Страница 21: ...ProNet Series ACServoUser sManual 19 ProNet 1AD 1ED 2BD ProNet 02B ProNet E 02B...
Страница 22: ...ProNet Series ACServoUser sManual 20 ProNet 04B ProNet E 04B ProNet 08B ProNet E 08B...
Страница 163: ...ProNet Series ACServoUser sManual 161 ProNet 75D 1AD 1ED 2BD Unit mm Air Flow Air Flow Air Flow...
Страница 193: ......