Setup & Operation 11. I/O Remote Settings
64
RC180 Rev.17
11. I/O Remote Settings
This section describes the functions and timings of input and output signals.
The remote functions may be assigned to your standard I/O board(s), expansion I/O
board(s), or fieldbus I/O board(s) to enhance robot system control - either from an
operational unit of your choice or a sequencer.
Remote function is initially assigned to both input and output from 0 to 7.
To accept external remote inputs, assign the remote function and the control device is
remote. For further details, refer to the section,
Remote Control Software Configuration
in
EPSON RC+ 5.0 User’s Guide 10. Remote Control
.
The user defines the I/O number that a remote function is assigned to using software
configuration. For further details, refer to the section,
Remote Control Software
Configuration
in
EPSON RC+ 5.0 User’s Guide 10. Remote Control
.
For details about I/O cable connection, refer to sections on
Setup & Operation 10. I/O
Connector
and
12.2. Expansion I/O Board (Option)
and
12.3 Fieldbus I/O Board (Option)
.
For details about communication with external equipment, refer to
EPSON RC+ 5.0
User’s Guide 10. Remote Control
.
CAUTION
■ When using remote I/O, always make sure of the following. Using the robot
system under unsatisfactory conditions may cause malfunction of the system
and/or safety problems.
-
Assign remote functions to inputs/outputs correctly and wire correctly when
setting up remote I/O signals.
-
Make sure that the functions correspond to the correct input/output signals
before turning ON the system.
-
When verifying the robot system operation, prepare for failures with initial
settings or wiring. If the Manipulator functions unusually by the failures with
initial settings or wiring, press the Emergency Stop switch immediately to
stop the Manipulator.
Remote function is available when virtual I/O is enabled.
When you set up a remote I/O signal, please either keep a written record of the settings or
store the data in a file for later reference.
When you set up a fieldbus I/O signal to the remote function, response depends on the
baud rate of the fieldbus. For details of fieldbus response, refer to
Setup & Operation
12.3.2 Response Speed of Fieldbus I/O
.
NOTE
NOTE
NOTE
Содержание RC180
Страница 1: ...Rev 17 EM164C3205F ROBOT CONTROLLER RC180 ...
Страница 2: ...ROBOT CONTROLLER RC180 Rev 17 ...
Страница 13: ...Safety This section contains information for safety of the Robot System ...
Страница 14: ......
Страница 19: ...Setup Operation This section contains information for setup and operation of the Robot Controller ...
Страница 20: ......
Страница 124: ...Setup Operation 12 Option Units 112 RC180 Rev 17 ...
Страница 125: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Страница 126: ...114 ...