Maintenance 6. Maintenance Parts Replacement Procedures
RC180 Rev.17
145
6.1.3 Cleaning and Replacing the Option Unit Fan Filter
Option Unit
Fan Filter
Remove
(1) Turn OFF the Controller.
(2) Remove the mounting screw for each fan
filter located on the top and the bottom of
the Option Unit.
Two fan filters are mounted on the
Option Unit. Be sure to replace both at
the same time.
Clean the fan filter when it is necessary.
Fan Filters
Screws
Option Unit
Fan Filter
Mount
(1) Insert the fan filters into the Option Unit and secure each of them with a screw.
(2) Plug in the power connector. Turn ON the Controller and make sure that the
Controller starts properly without any vibration or abnormal noise.