Maintenance 8. Trouble Shooting
RC180 Rev.17
194
No.
Message
Remedy
Note 1
Note 2
2345
I/O input/output byte number is out of
available range or the board is not
installed.
Review the program.
Check whether the expansion I/O board
and Fieldbus I/O board are correctly
detected.
Byte number
2346
I/O input/output word No. is out of
available range or the board is not
installed.
Review the program.
Check whether the expansion I/O board
and Fieldbus I/O board are correctly
detected.
Word number
2347
Memory I/O bit number is out of
available range.
Review the program.
Bit number
2348
Memory I/O byte number is out of
available range.
Review the program.
Byte number
2349
Memory I/O word number is out of
available range.
Review the program.
Word number
2350
Command allowed only when virtual
I/O mode is active.
The command can be executed only for
virtual I/O mode.
2351
Cannot change the status for CC-Link
system area.
2352
Remote setup error. Cannot assign
CC-Link system area to remote
function.
2360
File failure. Failed to open the
configuration file.
Restore the controller configuration.
2361
File failure. Failed to close the
configuration file.
Restore the controller configuration.
2362
File failure. Failed to open the key of
the configuration file.
Restore the controller configuration.
2363
File failure. Failed to obtain the string
from the configuration file.
Restore the controller configuration.
2364
File failure. Failed to write in the
configuration file.
Restore the controller configuration.
2365
File failure. Failed to update the
configuration file.
Restore the controller configuration.
2370
The string combination exceeds the
maximum string length.
The maximum string length is 255.
Review the program.
Combined
string length
2371
String length is out of range.
The maximum string length is 255.
Review the program.
The
specified
length
2372
Invalid character is specified after the
ampersand in the Val function.
Review the program.
2373
Illegal string specified for the Val
function.
Review the program.
2374
String Failure. Invalid character code
in the string.
Review the program.
2380
Cannot use ' 0 ' for Step value in
For...Next.
Check the Step value.
2381
Relation between For...Next and
GoSub is invalid. Going in or out of a
For...Next using a Goto statement.
Review the program.
2382
Cannot execute Return while executing
OnErr.
Review the program.
2383
Return was used without GoSub.
Review the program.
Review the program.
2384
Case or Send was used without Select.
Review the program.
Review the program.
Содержание RC180
Страница 1: ...Rev 17 EM164C3205F ROBOT CONTROLLER RC180 ...
Страница 2: ...ROBOT CONTROLLER RC180 Rev 17 ...
Страница 13: ...Safety This section contains information for safety of the Robot System ...
Страница 14: ......
Страница 19: ...Setup Operation This section contains information for setup and operation of the Robot Controller ...
Страница 20: ......
Страница 124: ...Setup Operation 12 Option Units 112 RC180 Rev 17 ...
Страница 125: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Страница 126: ...114 ...