Setup & Operation 12. Option Units
84
RC180 Rev.17
Wiring (DeviceNet)
The DeviceNet connector is a 5 pin open connector. Use the connector attached to the
board for wiring.
Terminal name for each pin
Terminal No
Terminal Name
1
V-
2
CAN_L
3
SHELD
4
CAN_H
5
V+
Prepare the cable for DeviceNet sold in the market as a communication cable.
Install terminating resistors at both ends of the network.
DeviceNet Confirmation with EPSON RC+ 5.0
When the DeviceNet board is installed to the Controller, it is recognized automatically.
Confirm whether EPSON RC+ 5.0 has recognized the DeviceNet board using the
following procedure.
(1)
Select EPSON RC+ 5.0 menu-[Setup]-[Controller] to display the [Setup Controller]
dialog.
(2)
(4)
(3)
(3)
(3)
(2)
Select [Inputs / Outputs].
(3)
Make sure that the following are displayed.
Fieldbus-Installed
: Yes
Feildbus Type
: DeviceNet
Fieldbus Slave ID
: (MAC address depending on the setting)
(4)
Click the <Close> button.
Operation
For details, refer to
12.3.9 Operation
.
Electronic Information File (EDS file)
An EDS file is supplied for DeviceNet network configuration. The file is located in the
following folder in the Manual Update CD that is attached to the Robot Controller.
\EpsonRC50\Fieldbus\DeviceNet
NOTE
Содержание RC180
Страница 1: ...Rev 17 EM164C3205F ROBOT CONTROLLER RC180 ...
Страница 2: ...ROBOT CONTROLLER RC180 Rev 17 ...
Страница 13: ...Safety This section contains information for safety of the Robot System ...
Страница 14: ......
Страница 19: ...Setup Operation This section contains information for setup and operation of the Robot Controller ...
Страница 20: ......
Страница 124: ...Setup Operation 12 Option Units 112 RC180 Rev 17 ...
Страница 125: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Страница 126: ...114 ...