Maintenance 8. Trouble Shooting
RC180 Rev.17
195
No.
Message
Remedy
Note 1
Note 2
2385
Cannot execute EResume while
executing GoSub.
Review the program.
2386
EResume was used without OnErr.
Review the program.
Review the program.
2400
Curve failure. Failed to open the Curve
file.
Reboot the controller.
Create a Curve file again.
2401
Curve failure. Failed to allocate the
header data of the curve file.
Reboot the controller.
Create a Curve file again.
2402
Curve failure. Failed to write the curve
file.
Reboot the controller.
Create a Curve file again.
2403
Curve failure. Failed to open the curve
file.
Reboot the controller.
Create a Curve file again.
2404
Curve failure. Failed to update the
curve file.
Reboot the controller.
Create a Curve file again.
2405
Curve failure. Failed to read the curve
file.
Reboot the controller.
Create a Curve file again.
2406
Curve failure. Curve file is corrupt.
Reboot the controller.
Create a Curve file again.
2407
Curve failure. Specified a file other
than the curve file.
Reboot the controller.
Create a Curve file again.
2408
Curve failure. Version of the curve file
is invalid.
Reboot the controller.
Create a Curve file again.
2409
Curve failure. Robot number in the
curve file is invalid.
Reboot the controller.
Create a Curve file again.
2410
Curve failure. Cannot allocate enough
memory for the CVMove statement.
Reboot the controller.
2411
Specified point data in the Curve
statement is beyond the maximum
count.
The maximum number of points
specified in the Curve statement is 200.
Review the program.
2412
Specified number of output commands
in the Curve statement is beyond the
maximum count.
The maximum number of output
commands specified in the Curve
statement is 16. Review the program.
2413
Curve failure. Specified internal code
is beyond the allowable size in Curve
statement.
Reboot the controller.
2414
Specified continue point data P(:) is
beyond the maximum count.
The maximum number of points
specified continuously is 200. Review
the program.
Start point
End point
2415
Curve failure.
Cannot create the curve file.
Reboot the controller.
Create a Curve file again.
2416
Curve file does not exist.
Check whether the specified Curve file
name is correct.
2417
Curve failure. Output command is
specified before the point data.
Check whether no output command is
specified before the point data.
2418
Curve file name is too long.
Check whether the specified Curve file
name is correct. The maximum string
length of the file name is 32.
2419
Curve failure.
Curve file path is too long.
Check whether the specified Curve file
name is correct.
2420
Curve file name is invalid.
2430
Error message failure. Error message
file does not exist.
Reboot the controller.
Содержание RC180
Страница 1: ...Rev 17 EM164C3205F ROBOT CONTROLLER RC180 ...
Страница 2: ...ROBOT CONTROLLER RC180 Rev 17 ...
Страница 13: ...Safety This section contains information for safety of the Robot System ...
Страница 14: ......
Страница 19: ...Setup Operation This section contains information for setup and operation of the Robot Controller ...
Страница 20: ......
Страница 124: ...Setup Operation 12 Option Units 112 RC180 Rev 17 ...
Страница 125: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Страница 126: ...114 ...