Maintenance 6. Maintenance Parts Replacement Procedures
162
RC180 Rev.17
6.7.2 Mount Option Unit 1
(1) Secure Option Unit 1 with two screws each on front side and backside.
(2) Connect the flat cable connector to the backside of
Option Unit 1.
Connecting Connector
Option Unit 1
Back of Controller
Main Chassis
(3) Secure the backside cover to Option Unit 1 with two screws.
Orient the cover so that there is no gap when mounted.
(4) Plug in the power connector. Turn ON the Controller and make sure that the
Controller starts properly without any vibration or abnormal noise.
6.7.3 Remove Option Unit 2
(1) Turn OFF the Controller and unplug the power connector.
(2) Disconnect the cables connected to the Option Unit board.
(3) Remove two screws on each unit from the
backside of Option Units 1 and 2 to remove the
covers.
(4) Pull out the flat cable connector connected on the
backside of Option Units 1 and 2.
Compress both ends of the connector to pull out
the connector.
NOTE