Setup & Operation 12. Option Units
88
RC180 Rev.17
PROFIBUS-DP Confirmation with EPSON RC+ 5.0
When a PROFIBUS-DP board is installed to the Controller, it is recognized automatically.
Confirm whether EPSON RC+ 5.0 has recognized the PROFIBUS-DP board using the
following procedure.
(1)
Select EPSON RC+ 5.0 menu-[Setup]-[Controller] to display the [Setup Controller]
dialog.
(2)
(4)
(3)
(3)
(3)
(2)
Select [Inputs / Outputs].
(3)
Make sure that the following are displayed.
Fieldbus-Installed
: Yes
Fieldbus Type
: PROFIBUS DP
Fieldbus Slave ID
: (depends on the address configure switch)
(4)
Click the <Close> button.
Operation
For details, refer to
12.3.9 Operation
.
Electronic Information File (GSD file)
A GSD file (EPSN0A4C.gsd) is supplied for PROFIBUS-DP network configuration. The
file is located in the following folder in the Manual Update CD that is attached to the
Robot Controller.
\EpsonRC50\Fieldbus\PROFIBUS