Maintenance 6. Maintenance Parts Replacement Procedures
160
RC180 Rev.17
(7) Pull out the DPB cable connector (CN1)
and remove the intermediate plate.
CN1
Fuse
(8) Pull out the fuse in direction of the arrow.
Pull the wires to the side to allow
clearance for pulling out the fuse.
Fuse
Mount
(1) Hold the intermediate plate to connect the DPB cable connector (CN1).
(2) Mount the intermediate plate to the Controller and secure the four mounting screws
and the FG mounting screws (G / RS: 2 screws, C3 / S5: 3 screws) removed in steps
(5) and (6).
Be sure to keep the cable from being trapped or damaged.
(3) Mount the Motor Driver Module.
Refer :
Maintenance 6.3.2 Replacing Motor
(4) Mount the fan unit.
Refer :
Maintenance 6.1.2 Replacing Fan Unit
(5) Mount the Option Unit when it was installed.
Refer :
Maintenance 6.7.2 Mount Option Unit 1
Maintenance 6.7.6 Mount Option Unit 1, 2
(6) Plug in the power connector. Turn ON the Controller and make sure that the
Controller starts properly without any vibration or abnormal noise.
NOTE