Setup & Operation 12. Option Units
RC180 Rev.17
105
Wiring (PROFINET)
PROFINET connector is
RJ45 connector.
Use cable 100 BASE-TX (STP type).
CAUTION
Be sure to use cables and connectors complying with the industrial standards or
noise resistant Ethernet cable (STP cable). If you use an office use product or
UTP cable, it may cause communication errors and may not offer the proper
performance.
PROFINET Confirmation with EPSON RC+ 5.0
When PROFINET board is installed in the controller, it is recognized automatically.
Confirm that EPSON RC+ 5.0 has recognized the board in the following procedure.
(1)
Select EPSON RC+ 5.0 menu-[Setup]-[Controller] to display the [Setup Controller]
dialog.
(2)
(3)
(2)
Select the [Inputs / Outputs].
(3)
Make sure that following is displayed.
Fieldbus
: Yes
(4)
Click the “+” displayed on the left of [Input / Output] and select the [General].
(4)
(5)
(6)
(5)
Make sure that following is displayed.
Fieldbus Type
: PROFINET IO