Setup & Operation 12. Option Units
104
RC180 Rev.17
PROFINET Appearance
RJ45 Connector
Status Display LED
MS
C
S
L
NK
/A
CT
MS LED
: Module status display
CS LED
: IO Controller
connection status
display
LNK/ACT LED : Link status /
Communication packet
reception or
transmission status
display
Refer to the following table for functions
of LEDs.
LED Description of PROFINET
LED status represents the status of the fieldbus board.
LED status
MS
CS
LNK/ACT
OFF
Power OFF or
Device is being initialized
Offline
No link or
Power OFF
G
RN
ON
Normal operation
Offline
IO controller is in RUN
Linking
Blinking
-
-
Receiving/transmitting
communication packet
Blinking once Evaluating
Offline /
IO controller is in STOP
-
R
ED
B
lin
k
in
g
Blinking
once
Structure Error
- Too many (Sub) Modules
- I/O size set by IO controller
is too large.
- Structure mismatched
(No module, wrong module)
-
-
Blinking
3 times
No station name has been set or
No IP address has been set
-
-
Blinking
4 times
Internal error
-
-
Board Configuration (PROFINET)
PROFINET settings such as the communication setting are all configured by the
development software (EPSON RC+ 5.0). You don’t need to configure anything about
PROFINET board.
Содержание RC180
Страница 1: ...Rev 17 EM164C3205F ROBOT CONTROLLER RC180 ...
Страница 2: ...ROBOT CONTROLLER RC180 Rev 17 ...
Страница 13: ...Safety This section contains information for safety of the Robot System ...
Страница 14: ......
Страница 19: ...Setup Operation This section contains information for setup and operation of the Robot Controller ...
Страница 20: ......
Страница 124: ...Setup Operation 12 Option Units 112 RC180 Rev 17 ...
Страница 125: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Страница 126: ...114 ...