Maintenance 8. Trouble Shooting
RC180 Rev.17
230
No.
Message
Remedy
Note 1
Note 2
5050
Over speed during torque control.
Check the work motion speed range.
Check the motion speed during torque
control.
5051
15V PWM drive power supply failure.
Reboot the controller. Replace the 15V
power supply.
Check the 15V power supply and cable
connection.
Replace the motor driver.
Replace the DMB.
5054
Overload of the motor. Decrease the
motion duty and the Accel.
Lower the motion duty.
Check the Weight/Inertia setting.
Check the robot. (Backlash, large load,
loose belt tension, brake)
5055
Overload of the motor. Decrease the
operation duty and the Accel.
Lower the motion duty.
Check the Weight/Inertia setting.
Check the robot. (Backlash, large load,
loose belt tension, brake)
5056
G sensor output failure.
Check the control board.
Check the noise countermeasures.
Replace the control board.
5072
Servo alarm B.
Reboot the controller.
5080
Motor is overloaded. Decrease the
duty and the Accel.
Lower the motion duty.
Check the Weight/Inertia setting.
Check the robot. (Backlash, large load,
loose belt tension, brake)
5098
High temperature of the encoder.
Decrease the duty. Check the
reduction gear unit of the robot.
Wait until the temperature of the encoder
decreases.
Lower the motion duty.
Check the Weight/Inertia setting.
Check the robot. (Backlash, large load,
loose belt tension, brake)
5099
High temperature of the motor driver .
Clean the controller fan filter. Check
the ambient temperature. Decrease the
duty.
Clean the cooling fan filter.
Lower the motion duty.
Check the Weight/Inertia setting.
Lower the ambient temperature.
5112
Servo alarm C.
Reboot the controller.
Содержание RC180
Страница 1: ...Rev 17 EM164C3205F ROBOT CONTROLLER RC180 ...
Страница 2: ...ROBOT CONTROLLER RC180 Rev 17 ...
Страница 13: ...Safety This section contains information for safety of the Robot System ...
Страница 14: ......
Страница 19: ...Setup Operation This section contains information for setup and operation of the Robot Controller ...
Страница 20: ......
Страница 124: ...Setup Operation 12 Option Units 112 RC180 Rev 17 ...
Страница 125: ...Maintenance This section contains maintenance procedures for the Robot Controller ...
Страница 126: ...114 ...