Maintenance 6. Maintenance Parts Replacement Procedures
RC180 Rev.17
163
(5) Secure a backside cover to Option Unit 1 with
two screws.
Orient the cover so that there is no gap when
mounted.
Be sure to keep the cable from being trapped or
damaged.
(6) Remove two screws each on the front
side and backside and remove Option
Unit 2 in the direction shown by the
arrow.
When replacing Option Unit 2.
The removal procedure is complete.
When Option Unit 2 in not used.
Perform steps (7) to (9).
(7) Remove four screws and remove the Option
Unit mounting bracket from the Option Unit
1.
Option Unit
Mounting
Brackets
(8) Remove the Option Unit 2 filter units (two places).
Refer :
Maintenance 6.1.3 Cleaning and Replacing Fan Filter
(9) Mount the fan filters (two places) to Option
Unit 1.
Filter Units
Mounted
NOTE