66
EN
Reason:
Overheating in the water tank.
Solution
: See point #1 „overheating limiter fuse“. Restart the generator.
Fault
:
Steam outlet spits hot water.
Reason:
Water foaming.
Solution
: Check if the water may be foaming due to contamination with oils or
similar substances. Clean the tank if necessary.
Reason:
Steam pipe installed incorrectly, steam pipe blocked by condensed water.
Solution
: Make sure the steam pipe is not blocked by condensed water. If neces-
sary a syphon may need to be installed. Make sure the steam can go through the
pipe freely.
Reason:
Water level probe fault.
Solution
: Inspect the water level probe, clean if necessary. Make sure that the
float can move freely. See chapter „installation > water level probe“.
Fault
:
No steam produced (heating does not start)
Reason:
Overheating limiter fuse released.
Solution
: Overheating due to too low water level. Reset the limiter fuse by
pushing firmly on the reset button located on the bottom side of the generator
under the rubber cap (see page 12). Inspect the generator for possible reasons for
overheating. Attention! Allow min. 5 minutes to cool down the generator.
Fault
:
Essence fault
Reason:
Essence level in the container too low or connection cable to the level
probe interrupted.
Solution
: Refill essence, check the cable connection to the level probe.
16. Disposal
The electric devices which are no longer required shall be recycled as per EU guideline 2012/19/EU