62
EN
Fan operation time by cabin-dry mode
Here you set how long the fan(s) will operate after the main cabin operation time. Default setting
is 30 minutes. In order to use this function the fan(s) should be connected to the outputs Fan 1
and /or Fan 2.
This function helps to dry the cabin after use.
Drain the water tank
This functions allows to manually drain the water tank. Tip briefly twice on the symbol to open a
sub-menu.
In the sub-menu you can then either launch the drain
(start) or
go back (cancel).
Note
: Manual drain will interrupt the heating is the generator is on. This function may be helpful
for servicing and maintenance purposes.
Descaling
In this sub-menu you can launch the descaling cycle manually. Tap on this symbol to open the sub
menu.
In the sub-menu you can then either launch the drain
(start) or
go back (cancel).
By running descaling the symbol
will appear in blue on the main screen in the bottom. Tap on
this symbol to check the remaining time until the end of the cycle.
Essence dosing
In this menu you can set the operation parameters for the dosing pumps 1 and 2:
•
Dosing time
- pump operation time in seconds per single injection cycle. Range 1 - 30
seconds.
•
Dosing interval
- intervals in minutes between injection cycles. Range1 - 30 minutes.
The selection of the pump, start and stop are effected from the main interface (see “Operation”).
Bench heating
Here you can configure the control for the external bench heating - hysteresis range 1 - 5 K and
temperature from 20 to 40°C.
Notice
: The optionally available bench heating temperature sensor must be connected if you wish
to use this function.
Floor heating
Here you can configure the control for the external floor heating - hysteresis range 1 - 5 K and
temperature from 20 to 40°C.
Notice
: The optionally available floor heating temperature sensor must be connected if you wish
to use this function.