33
EN
8.10 Power output adjustment
SteamRock Premium steam generators allow to quickly adjust the power output upon installa-
tion on site. You can reduce or increase the steam production in order to suit the steam room
cabin size and construction. This adjustment may be also done at a later time if required.
The power adjustment is made with the jumper JP1 on the main
board.
Possible power range:
•
SteamRock Premium 18 kW: 9 kW, 12 kW, 15 kW, 18 kW
•
SteamRock Premium 9 kW: 3 kW, 6 kW, 9 kW
SteamRock Premium 18 kW:
A
B
Power
Steam qty kg/h
0
0
9 kW
12 kg/Std
B
0
12 kW
16 kg/Std
0
B
15 kW
20 kg/Std
B
B
18 kW
24 kg/Std
SteamRock Premium 9 kW:
A
B
Power
Steam qty kg/h
0
0
3 kW
4 kg/Std
B
0
6 kW
8 kg/Std
0
B
9 kW
12 kg/Std
The above given quantities represent the max. possible quantities by continuous operation and
3 bar water pressure. Real steam production is usually smaller and depends on the temperature
setting and steam room construction.
JP1 jumper for power
adjustment
0 = open
B = closed (set)
Risk of scalding
Upon commissioning it is obligatory to verify through practical tests that the selected
power setting may not drive air temperature inside the steam room over 50°C.
Connect the 2-core
red
cable at the bottom of
the steam generator to the corresponding ter-
minals of the optional container for essences.
The ends of this cable are bridged by default.
Remove the bridge before connection.
If you wish to connect two containers with
essences connect the level probes as shown
below. The intermediate cable (1 m, white), is
included with delivery.
Connection of the level
probe for essence dosing
(optional)