10
EN
3. Specifications
Dimensions H x W x D [mm]
670 x 460 x 350 mm
Weight
28 kg (Type 1 - 9 kW) / 30 kg (Type 2 - 18 kW)
Water supply pressure [bar]
2 - 8 bar
Operation pressure max. [bar]
Pressureless system. With overpressure release valve.
Performance at 3 bar [steam/h]
3 kW - 4 kg/h, 6 kW - 8 kg/h, 9 kW - 12 kg/h, 12 kW - 16
kg/h, 15 kW - 20 kg/h, 18 kW - 24 kg/h
Protection class
IP x4
Water tank
Stainless steel, accessible via opening lid
Internal overheating protection
2-level system with water temperature sensor and
separate overheating limiter fuse
Heating system
Heating elements on the outer side of the water tank,
switchable in 3 kW steps
Cleaning and drain system
Integrated automatic descaling and draining system,
external 5 l container for cleaning liquid.
Attention - use only non-foaming cleaners!
Drain
1“ pipe on the water tank bottom
Water level control
Automatic via level probe, automatic water refilling
Control unit
Integrated control unit with external cable-connect-
ed Emotouch 3 display panel
Sensor system
Incl. cabin air temperature sensor, 5 m cable.
Optional - temperature sensor for floor and bench
temperature control
Essence dosing
Integrated, with 2 built-in dosing pumps
Water supply
¾“ external thread
Steam output
1 1/4“ external thread, incl. 2-part brass union
Outputs / connections
•
Light - 230 V AC, dimmable
•
2 x fan - 230 V AC
•
AUX - volt-free output
•
Floor heating - volt-free output
•
Bench heating - volt-free output
•
4 x saunabus (S-Bus) connector (RJ12) for display /
modules
•
1 x essence level control (optional)
•
Mass storage connector (type A) in display panel
Power supply
400V 3N AC, 50/60 Hz
premounted 2 m mains cord with Cekon type plug