59
EN
Settings
Service- / maintenance intervals
Choose this option to set the service and maintenance intervals. Every time the unit is turned on
after the set time is over, a reminder and the stored contact details will be displayed briefly. End
customers can check the remaining time by choosing „Advanced Settings“ at any time. This also
allows you to calculate the operating hours.
Factory default for private users - 500 hours.
Factory default for commercial users - 2500 hours.
Fan
Here you can make settings for both fan outputs (fan 1 and fan 2). Touch the symbol twice to open
settings sub-menu. Following options are available:
•
„
Steam
“ - fan runs when steam is produced. Touch the symbol of the fan 1 and/or fan 2, to
assign them this mode. Symbol highlighted in white - function active, symbol in grey - func-
tion not assigned.
•
„
Steam pause
“ - fan runs only when the steam production is paused (generator stops
because the temperature exceeds the set point). If the generators start again the fan will
temporarily stop. You can assign this mode likewise to the fan 1 and/or fan 2.
•
„
Cabin dry
“ - fan will start after the main operation to dry the cabin (running time may be
set separately to 0-30 minutes). You can assign this mode likewise to the fan 1 and/or fan 2.
Example: fan 1 set to „steam“, fan 2 set to „steam pause“, both fans set to „cabin dry“.
The fan 1, as a blower, runs continuously. The fan 2, as an extractor fan, runs only if the set-point
has been reached and there is no steam production. After the operation both fans will switch on
to evacuate humidity and dry the cabin faster.
Hysteresis
You can set the hysteresis in a range 1K to 5°C. This will adjust the upper and lower temperature
limit at which the heating switches on or off again. For example, at a target temperature of 46°C
and an hysteresis of 4K, the system will try to keep the temperature within 44°C - 48°C range. This
allows you to adjust the temperature control more precisely to the specific steam room.
Generally for steam rooms we recommend low hysteresis values of no more than 4K and the
appropriate testing upon installation.
By 1K setting the hysteresis means „-1°C“. By set point e.g. 46°C this means the heating will stop at
46°C and re-start at 45°C.
Type of use
Choose this option to select between domestic or commercial use. This will influence the heating
time limitation. Home use - max. 6 hours, commercial use - up to unlimited possible.