Technical data
Proline Cubemass C 100 HART
106
Hauser
16.6 Performance characteristics
Reference operating
conditions
• Error limits based on ISO 11631
• Water with +15 to +45 °C (+59 to +113 °F) at2 to 6 bar (29 to 87 psi)
• Specifications as per calibration protocol
• Accuracy based on accredited calibration rigs that are traced to ISO 17025.
To obtain measured errors, use the
Applicator
sizing tool → 99
Maximum measured error
o.r. = of reading; 1 g/cm³ = 1 kg/l; T = medium temperature
Base accuracy
Mass flow and volume flow (liquids)
±0.10 % o.r.
Mass flow (gases)
±0.50 % o.r.
Density (liquids)
Under reference conditions
Standard density calibration
Wide-range
Density specification
[g/cm³]
[g/cm³]
[g/cm³]
±0.0005
±0.02
±0.002
1)
Valid over the entire temperature and density range
2)
Valid range for special density calibration: 0 to 2 g/cm³, +5 to +80 °C (+41 to +176 °F)
3)
Order code for "Application package", option EE "Special density"
Temperature
±0.5 °C ± 0.005 · T °C (±0.9 °F ± 0.003 · (T – 32) °F)
Zero point stability
DN
Zero point stability
[mm]
[in]
[kg/h]
[lb/min]
1
¹⁄₂₄
0.0008
0.00003
2
¹⁄₁₂
0.002
0.00007
4
¹⁄₈
0.014
0.0005
6
¹⁄₄
0.02
0.0007
Flow values