Commissioning
Proline Cubemass C 100 HART
62
Hauser
Parameter overview with brief description
Parameter
Description
Selection / User entry
Factory setting
Operating mode
Define the output as a pulse, frequency or
switch output.
• Pulse
• Frequency
• Switch
Pulse
Switch output function
Select function for switch output.
• Off
• On
• Diagnostic behavior
• Limit
• Flow direction check
• Status
Off
Assign diagnostic behavior
Select diagnostic behavior for switch output. • Alarm
• Alarm or warning
• Warning
Alarm
Assign limit
Select process variable for limit function.
• Mass flow
• Volume flow
• Corrected volume flow
• Target mass flow
• Carrier mass flow
• Density
• Reference density
• Dynamic viscosity
• Concentration
• Kinematic viscosity
• Temp. compensated
dynamic viscosity
• Temp. compensated
kinematic viscosity
• Temperature
• Totalizer 1
• Totalizer 2
• Totalizer 3
• Measuring tube damping
Mass flow
Assign flow direction check
Select process variable for flow direction
monitoring.
• Off
• Volume flow
• Mass flow
• Corrected volume flow
Mass flow
Assign status
Select device status for switch output.
• Partially filled pipe detection
• Low flow cut off
Partially filled pipe detection
Mass flow unit
Select mass flow unit.
Result
The selected unit applies for:
• Output
• Low flow cut off
• Simulation process variable
Unit choose list
Country-specific:
• kg/h
• lb/min
Volume flow unit
Select volume flow unit.
Result
The selected unit applies for:
• Output
• Low flow cut off
• Simulation process variable
Unit choose list
Country-specific:
• l/h
• gal/min (us)
Unit totalizer
Select process variable totalizer unit.
Unit choose list
kg
Switch-on value
Enter measured value for the switch-on
point.
Signed floating-point number
0 kg/h
Switch-off value
Enter measured value for the switch-off
point.
Signed floating-point number
0 kg/h
Switch-on delay
Define delay for the switch-on of status
output.
0.0 to 100.0 s
0.0 s
Содержание Proline Cubemass C 100 HART