Commissioning
Proline Cubemass C 100 HART
68
Hauser
10.2.9 Configuring the low flow cut off
The
Low flow cut off
submenu contains parameters that must be configured for the
configuration of low flow cut off.
Navigation
"Setup" menu → Low flow cut off
Low flow cut off
→
Assign process variable
On value low flow cutoff
Off value low flow cutoff
Pressure shock suppression
Parameter overview with brief description
Parameter
Prerequisite
Description
Selection / User
entry
Factory setting
Assign process variable
–
Select process variable for low
flow cut off.
• Off
• Mass flow
• Volume flow
• Corrected volume
flow
Mass flow
On value low flow cutoff
One of the following options is
selected in the
Assign process
variable
parameter:
• Mass flow
• Volume flow
• Corrected volume flow
Enter on value for low flow cut
off.
Positive floating-
point number
For liquids: depends
on country and
nominal diameter
Off value low flow cutoff
One of the following options is
selected in the
Assign process
variable
parameter:
• Mass flow
• Volume flow
• Corrected volume flow
Enter off value for low flow cut
off.
0 to 100.0 %
50 %
Pressure shock suppression
One of the following options is
selected in the
Assign process
variable
parameter:
• Mass flow
• Volume flow
• Corrected volume flow
Enter time frame for signal
suppression (= active pressure
shock suppression).
0 to 100 s
0 s