Firmware V3.15
21.04.2021
295/401
•
•
Menu 1-5 Alarm
ALARM Pos: XXXXX
Alarm Relay XXX
Current ON/OFF status of alarm output Terminal 15/16/18
Hi Temp Setp.1 XX °C
High temperature setpoint Zone 1
Lo Temp Setp.1 XX K
Low temperature setpoint Zone 1
Hi Temp Setp.2 XX °C
High temperature setpoint Zone 2;Only shown when two-zone operation is set
(Menu 6-1)
Lo Temp Setp.2 XX K
Low temperature setpoint Zone 2;Only shown when two-zone operation is set
(Menu 6-1)
Menu 1-6 Pane Heater
PANE HTR XXXXX
Pane Heater xxx
Current OFF/ON status of
pane heater output Terminal 73/74
Run Time xxx %
Current on time of frame heater
Humidity xxx %
Current ambient air humidity (transmitted via CAN bus from pack controller with fitted
ambient humidity sensor)
Room temp xx °C
Current ambient air temperature (transmitted via CAN bus from pack controller with
fitted ambient temperature sensor
Содержание UA 400
Страница 26: ...Firmware V3 15 21 04 2021 26 401 Solenoid valve Relay for Solenoid Valve 1 ...
Страница 133: ...Firmware V3 15 21 04 2021 133 401 Upper case and lower case can be toggled by tapping the MODE button ...
Страница 172: ...Firmware V3 15 21 04 2021 172 401 Service Mode 6 7 2 SERVICE MOD ...
Страница 244: ...Firmware V3 15 21 04 2021 244 401 ...
Страница 324: ...Firmware V3 15 21 04 2021 324 401 COOLING 1 Pos XXXXX Hystersis R4 1 xxx K Supply air temperature hysteresis setpoint ...
Страница 357: ...Firmware V3 15 21 04 2021 357 401 COOLING 1 Pos XXXXX Hystersis R4 1 xxx K Supply air temperature hysteresis setpoint ...
Страница 361: ...Firmware V3 15 21 04 2021 361 401 FANS 2 Pos XXXXX Fan Delay Fan delay ...
Страница 372: ...Firmware V3 15 21 04 2021 372 401 ...