7.4 Mode of operation of the relay and transistor outputs
The table shows operation of the outputs for the separate controller types.
Relay outputs
230 V AC
Transistor outputs
24 V DC/50 mA
(91/92)
Controller type
Fan (ventilator)
Defrosting
Cooling
Alarm
Relay for switch off Frame/pane heater
*
Case controller
UA 111
inverted
positive
positive
inverted
–
inverted
UA 111 D
inverted
positive
positive
inverted
–
inverted
UA 121
inverted
positive
inverted
inverted
–
inverted
UA 131
–
positive
inverted
inverted
–
inverted
UA 131 LS with
advanced fan control
inverted
positive
inverted
–
–
inverted
UA 131 DD
inverted
positive
inverted
–
–
inverted
UA 141
–
positive
positive
inverted
positive
positive (Relay
73/74)
Room controller
UR 141 NK
positive
positive
positive
inverted
–
inverted
UR 141 TK
positive
positive
inverted
inverted
–
inverted
Содержание UA 400
Страница 26: ...Firmware V3 15 21 04 2021 26 401 Solenoid valve Relay for Solenoid Valve 1 ...
Страница 133: ...Firmware V3 15 21 04 2021 133 401 Upper case and lower case can be toggled by tapping the MODE button ...
Страница 172: ...Firmware V3 15 21 04 2021 172 401 Service Mode 6 7 2 SERVICE MOD ...
Страница 244: ...Firmware V3 15 21 04 2021 244 401 ...
Страница 324: ...Firmware V3 15 21 04 2021 324 401 COOLING 1 Pos XXXXX Hystersis R4 1 xxx K Supply air temperature hysteresis setpoint ...
Страница 357: ...Firmware V3 15 21 04 2021 357 401 COOLING 1 Pos XXXXX Hystersis R4 1 xxx K Supply air temperature hysteresis setpoint ...
Страница 361: ...Firmware V3 15 21 04 2021 361 401 FANS 2 Pos XXXXX Fan Delay Fan delay ...
Страница 372: ...Firmware V3 15 21 04 2021 372 401 ...