Firmware V3.13
21.04.2021
84/466
Example: Configuration of consecutive defrost
Defrost start
In the case of the CD Master controller, a defrost is triggered via the internal clock, the external contact or via
the manual defrost (CAN bus / local).
Configuration of the group members
The parameter "
FA-Funktion
" on the CD Master controller must be set to "Master". The parameter “
FA-Wartez
.”
specifies the wait time in minutes which the CD Master maintains between the defrosting of two groups. The
wait time applies equally to all groups.
The parameters “
FA-Gruppe
" and "
FA-Master
" are ignored on the CD Master and should be set to "
—
".
The parameter "
FA-Funktion
" on the CD Slaves must be set to “
Slave
”.
The parameter “
FA-Gruppe
" on the slave must be set so that the controller is defrosted in the desired group
with other controllers and/or in the desired sequence relative to other controllers. For the sake of clarity, the
group numbers should be assigned with the CAN bus address in ascending order and without gaps, but this is
not mandatory.
The CAN bus address of the CD Master is set for every slave using the parameter "FA-Master". This specifies
which of the controllers should coordinate / execute the defrost. The parameter “
FA-Wartez.
” is ignored by the
CD Slave and should be set to "—" . Similarly, the parameters for the defrost timer should be configured so that
no additional defrosts occur on the slave if additional defrosts outside the consecutive defrost are not desired.
For this, it is recommended to set all defrost times to "--" and to set the parameter “
Abtauuhr
” to “INT” (menu
3-2)..
Содержание Case Controller UA 4 E Series
Страница 23: ...Firmware V3 13 21 04 2021 23 466 For more details see chapter Operation UA 4xx E ...
Страница 135: ...Firmware V3 13 21 04 2021 135 466 Exit the menu by tapping the ESC button twice ...
Страница 157: ...Firmware V3 13 21 04 2021 157 466 Connection diagram UA 400 E CC One zode controller and two zone controller ...
Страница 158: ...Firmware V3 13 21 04 2021 158 466 Anschlussbild UA 401 E CC One zode controller ...
Страница 207: ...Firmware V3 13 21 04 2021 207 466 ...
Страница 216: ...Firmware V3 13 21 04 2021 216 466 SENSORS POS XXXXX Entry Default 5K3A1 Temperature range 0 100 C ...
Страница 277: ...Firmware V3 13 21 04 2021 277 466 ...
Страница 364: ...Firmware V3 13 21 04 2021 364 466 MODE POS XXXXX Entry Default Fixed run time Enthalpy ctrl rtm ...