Firmware V3.13
21.04.2021
144/466
•
•
•
•
6.6.1 Requirements for firmware update
The following components are required for a firmware update:
The controller for which the update is intended.
Special feature
: Two device generations are available. The DIP switch S3 provides a quick
distinguishing feature:
2nd generation controller
(from Oct. Nov. 2018)
with 9-pole DIP switch
1st generation controller
(since 2011)
with 8-pole DIP switch
Note:
The settings depend on the controller type!
Laptop or PC with Windows 7 / Windows 8 / Windows 10
USB A-B cable *
The following files are required for the firmware update *
- The installation program
"Firmware_Uploader_Setup_vxx.exe"
(download as ZIP file)
- The firmware files "
UA400_vx.xx.bin
", "
UA400_vx.xx.dfu" or "UA400_vx.xx.hex"
(download as ZIP
file)
Note:
After the download, all ZIP files must be extracted to any directory.
Step 1: Install software
Before the first connection
of the controller to the PC, the installation program
"
Firmware_Uploader_Setup_vxx.exe
" must first be executed
once
. Please follow the instructions given
by the installation wizard. The components to be installed can be selected in the following window.
Administrator rights and an existing internet connection required during the initial
installation!
With the operating systems Windows 2000, XP, Vista, Windows 7 and Windows
10, the PC
must
have an
existing internet connection
and the user
must
have
administrator rights
during installation while the installation program
"
Firmware_Uploader_Setup_vxx.exe
" is being executed. Administrator rights will also be
required when the controller is initially connected to the PC and the driver is installed by the
operating system. Following installation and the initial connection of the controller to the PC,
administrator rights are no longer required. In the event of questions concerning "administrator
rights under Windows", the responsible IT administrator should be consulted.
Содержание Case Controller UA 4 E Series
Страница 23: ...Firmware V3 13 21 04 2021 23 466 For more details see chapter Operation UA 4xx E ...
Страница 135: ...Firmware V3 13 21 04 2021 135 466 Exit the menu by tapping the ESC button twice ...
Страница 157: ...Firmware V3 13 21 04 2021 157 466 Connection diagram UA 400 E CC One zode controller and two zone controller ...
Страница 158: ...Firmware V3 13 21 04 2021 158 466 Anschlussbild UA 401 E CC One zode controller ...
Страница 207: ...Firmware V3 13 21 04 2021 207 466 ...
Страница 216: ...Firmware V3 13 21 04 2021 216 466 SENSORS POS XXXXX Entry Default 5K3A1 Temperature range 0 100 C ...
Страница 277: ...Firmware V3 13 21 04 2021 277 466 ...
Страница 364: ...Firmware V3 13 21 04 2021 364 466 MODE POS XXXXX Entry Default Fixed run time Enthalpy ctrl rtm ...