CAUTION: Handle each memory module only on either card edge, ensuring not to touch the middle of the memory
module. To avoid damaging components on the memory module, remove only one memory module at a time.
2.
To release the memory module from the socket, simultaneously press the ejectors on both ends of the memory module socket.
3.
Lift the memory module out of the socket by holding the memory module only by its edges.
Figure 25. Removing a memory module
Next steps
1.
Install the memory module.
2.
Install the air shroud.
3.
Install the sled into the enclosure.
4.
Follow the procedure listed in the After working inside your system section.
Installing the memory modules
Prerequisites
WARNING: The memory modules are hot to the touch for some time after the system has been powered down. Allow
time for the memory modules to cool before handling them. Handle the memory modules by the card edges and avoid
touching the components on the memory module.
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and
simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support
team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety
instructions that are shipped with your product.
1.
Follow the safety guidelines listed in the Safety instructions section.
2.
Follow the procedure listed in the Before working inside your system section.
3.
Remove the sled from the chassis.
4.
Remove the air shroud.
Steps
1.
Locate the appropriate memory module socket.
2.
Push out the ejectors on each end of the memory module socket.
3.
Align the memory module correctly with the alignment key of the memory module socket.
4.
Simultaneously press down firmly on both ends of the memory module with your thumbs until the module snaps into place.
CAUTION: Even pressure during insertion must be applied at both ends of the module simultaneously to prevent
damage to the socket. No pressure should be applied to the center of the module.
5.
Complete the latching of the module into the socket by applying inward pressure to the socket ejectors to ensure that the
ejectors are in a locked position. When the memory module is properly seated in the socket, the ejectors on the memory module
socket align with the ejectors on other identical sockets that have memory modules installed.
71
Содержание PowerEdge C6320p
Страница 1: ...Dell PowerEdge C6320p Owner s Manual Regulatory Model B08S Series Regulatory Type B08S004 ...
Страница 10: ...Figure 2 Supported configuration for the C6320p sled with an Intel Phi 72xx processor 10 ...
Страница 11: ...Figure 3 Supported configuration for the C6320p sled with an Intel Phi 72xx F processor 11 ...
Страница 25: ...Figure 16 Enclosure Service Tag location on the left front panel 25 ...
Страница 106: ...Figure 55 Removing an expansion card filler bracket 106 ...
Страница 152: ...Figure 95 Installing PDB 2 Figure 96 Installing the power cables and the power cable cover for PDB 2 152 ...