Figure 19. Inside the sled
1.
sled pull handle
2.
mezzanine card slot
3.
system battery
4.
memory slot (3)
5.
processor heat sink module
6.
air shroud
7.
1.8 inch Solid State Drive
8.
memory slot (3)
9.
PCIe riser slot
10.
sled release handle
PowerEdge C6320p sled
The PowerEdge C6320p sled is a server unit that is installed into the PE C6300 enclosure. The sled features a processor, memory,
slots for the PCIe expansion cards and onboard storage. Most of the hardware on the sled is dedicated for the sled.
Removing a sled
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and
simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support
team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety
instructions that are shipped with your product.
1.
Follow the safety guidelines listed in the Safety instructions section.
2.
Follow the procedure listed in the Before working inside your system section.
3.
Keep the Phillips #2 screwdriver ready.
NOTE: If the sled is not being replaced immediately, a sled blank needs to be installed to ensure proper cooling of the
system.
NOTE: The process of removing a sled blank is the same as the sled.
Steps
1.
Remove the screw that secures the retaining latch.
2.
Press the retaining latch and by using the handle, slide the sled out of the enclosure.
65
Содержание PowerEdge C6320p
Страница 1: ...Dell PowerEdge C6320p Owner s Manual Regulatory Model B08S Series Regulatory Type B08S004 ...
Страница 10: ...Figure 2 Supported configuration for the C6320p sled with an Intel Phi 72xx processor 10 ...
Страница 11: ...Figure 3 Supported configuration for the C6320p sled with an Intel Phi 72xx F processor 11 ...
Страница 25: ...Figure 16 Enclosure Service Tag location on the left front panel 25 ...
Страница 106: ...Figure 55 Removing an expansion card filler bracket 106 ...
Страница 152: ...Figure 95 Installing PDB 2 Figure 96 Installing the power cables and the power cable cover for PDB 2 152 ...