Table 31. Supported PSU configurations for non fabric processors
PSU
Sled configuration
1400 W
Supports up to 215 W processor, three hard drives, and four
memory modules per system board (Sled with Mellanox
ConnectX-4 embedded controller).
Supports up to 215 W processor, four hard drives, and four
memory modules per system board (Sled without Mellanox
ConnectX-4 embedded controller).
Supports up to 215 W processor, two hard drives, and six
memory modules per system board (Sled without Mellanox
ConnectX-4 embedded controller).
1600 W
Supports up to 245 W processor, two hard drives, and six
memory modules per system board (Sled with Mellanox
ConnectX-4 embedded controller).
Supports up to 245 W processor, four hard drives, and four
memory modules per system board (Sled with Mellanox
ConnectX-4 embedded controller).
Supports up to 245 W processor, six hard drives, and four
memory modules per system board (Sled without Mellanox
ConnectX-4 embedded controller).
Supports up to 245 W processor, three hard drives, and six
memory modules per system board (Sled without Mellanox
ConnectX-4 embedded controller).
Table 32. PSU supported configurations for fabric processors
PSU
Sled configuration
1400 W
Supports up to 230 W processor, two hard drives, and four
memory modules per system board
Support up to 230 W processor, four hard drives, and two
memory modules per system board
1600 W
Support up to 260 W processor, two hard drives, and six
memory modules per system board
Support up to 230 W processor, four hard drives, and four
memory modules per system board
Removing a power supply unit
Prerequisites
CAUTION: Many repairs may only be done by a certified service technician. You should only perform troubleshooting and
simple repairs as authorized in your product documentation, or as directed by the online or telephone service and support
team. Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety
instructions that are shipped with your product.
CAUTION: The system requires at least one working power supply unit (PSU) to operate.
1.
Follow the safety guidelines listed in the Safety instructions section.
2.
Follow the procedure listed in the Before working inside your system section.
3.
Disconnect the power cable from the power source and the PSU, and disconnect the peripherals.
139
Содержание PowerEdge C6320p
Страница 1: ...Dell PowerEdge C6320p Owner s Manual Regulatory Model B08S Series Regulatory Type B08S004 ...
Страница 10: ...Figure 2 Supported configuration for the C6320p sled with an Intel Phi 72xx processor 10 ...
Страница 11: ...Figure 3 Supported configuration for the C6320p sled with an Intel Phi 72xx F processor 11 ...
Страница 25: ...Figure 16 Enclosure Service Tag location on the left front panel 25 ...
Страница 106: ...Figure 55 Removing an expansion card filler bracket 106 ...
Страница 152: ...Figure 95 Installing PDB 2 Figure 96 Installing the power cables and the power cable cover for PDB 2 152 ...