Resolution
Refresh rate (Hz)
Color depth (bits)
1024 x 768
60, 75, 85
8, 16, 32
1152 x 864
60, 75, 85
8, 16, 32
1280 x 1024
60, 75
8, 16, 32
1440 x 900
60
8, 16, 32
Environmental specifications
NOTE: For additional information about environmental measurements for specific system configurations, see Dell.com/
environmental_datasheets.
Table 18. Temperature specifications
Temperature
Specifications
Storage
–40°C to 65°C (–40°F to 149°F)
Continuous operation (for altitude less than 950 m or
3117 ft)
10°C to 35°C (50°F to 95°F) with no direct sunlight on the equipment.
NOTE: Certain system configurations may require reductions in
the upper temperature limits.
Maximum temperature gradient (operating and storage) 20°C/h (36°F/h)
Table 19. Relative humidity specifications
Relative humidity
Specifications
Storage
5% to 95% (non-condensing)
Operating
20% to 80% (non-condensing) with a maximum humidity gradation of
10% per hour.
Table 20. Maximum vibration specifications
Maximum vibration
Specifications
Operating
0.26 G
rms
at 5 Hz–350 Hz (all operation orientations).
Storage
1.88 G
rms
at 10 Hz–500 Hz for 15 min (all six sides tested).
Table 21. Maximum shock specifications
Maximum shock
Specifications
Operating
One shock pulse in the positive z axis of 31 G for 2.6 ms in the
operational orientation
Storage
Six consecutively executed shock pulses in the positive and negative x, y,
and z axes (one pulse on each side of the system) of 27 G faired square
wave pulse with velocity change at 235 inches per second (597
centimeters per second)
31
Содержание PowerEdge C6320p
Страница 1: ...Dell PowerEdge C6320p Owner s Manual Regulatory Model B08S Series Regulatory Type B08S004 ...
Страница 10: ...Figure 2 Supported configuration for the C6320p sled with an Intel Phi 72xx processor 10 ...
Страница 11: ...Figure 3 Supported configuration for the C6320p sled with an Intel Phi 72xx F processor 11 ...
Страница 25: ...Figure 16 Enclosure Service Tag location on the left front panel 25 ...
Страница 106: ...Figure 55 Removing an expansion card filler bracket 106 ...
Страница 152: ...Figure 95 Installing PDB 2 Figure 96 Installing the power cables and the power cable cover for PDB 2 152 ...