SiUS341802E
Troubleshooting by Error Code
Service Diagnosis
234
2.46 Reactor Temperature Rise Abnormality
Error Code
L3
Applicable
Models
RXLQ72TATJU
Method of Error
Detection
Detect according to the value detected with the reactor surface thermistor.
Error Decision
Conditions
When the temperature detected with the reactor surface thermistor is more than the specified
temperature.
Supposed
Causes
Defective connection of harness
Defective reactor surface thermistor
Defective inverter PCB
Troubleshooting
Is
reactor
harness connected to
the terminal strip
correctly?
Is the wiring
disconnection in the
reactor surface
thermistor?
NO
YES
YES
NO
Connect the harness
correctly.
Replace the thermistor.
Replace the inverter PCB
(A3P).
Caution
Be sure to turn off the power switch before connecting or disconnecting
connectors, or parts may be damaged.
Содержание Aurora Series
Страница 316: ...Wiring Diagrams SiUS341802E 303 Appendix 1 Wiring Diagrams 1 1 Outdoor Unit RXLQ72TATJU 2D112580A ...
Страница 317: ...SiUS341802E Wiring Diagrams Appendix 304 RXLQ96 120TATJU 2D112581A ...
Страница 318: ...Wiring Diagrams SiUS341802E 305 Appendix RXLQ72TAYDU 2D112582A ...
Страница 319: ...SiUS341802E Wiring Diagrams Appendix 306 RXLQ96 120TAYDU 2D112583A ...
Страница 320: ...Wiring Diagrams SiUS341802E 307 Appendix RXLQ72 96 120TAYCU RXYQ72 96 120 144 168TAYCU 2D112579A ...
Страница 330: ...Wiring Diagrams SiUS341802E 317 Appendix 1 3 2 Energy Recovery Ventilator VAM Series VAM300 470 600GVJU 3D073269C ...
Страница 331: ...SiUS341802E Wiring Diagrams Appendix 318 VAM1200GVJU 3D073270C ...
Страница 332: ...Revision History Month Year Version Revised contents 04 2018 SiUS341802E First edition ...