Figure 6-65 People counting
Table 6-12 Parameter description of people counting
Parameters
Description
People Counting Alarm
Click Reset to reset the numbers of entry and exit.
Enter No.
Number of people that entered.
Exit No.
Number of people that exited.
Stay No.
The number of stay is the result of entry number minus exit
number. Alarm is triggered when the stay number reaches the
threshold.
Max Detect Height
0–300.
Min Detect Height
0–300.
Step 6
Select a schedule in the Deployment Time drop-down list.
Alarms are triggered only within the scheduled time.
Step 7
Click Actions to set alarm linkage actions. See "8.4.1 Alarm Actions" for detailed
information.
Step 8
Click Save.
6.4.3 Configuring In Area No.
The system counts the number of people in and out of the detection area. When the number of
entry or exit is larger or smaller than the threshold or when the dwell time of any person in the area
is greater than the threshold, an alarm is triggered.
Step 1
Click
, click
, and then select EVENT.
Step 2
Select a camera in the device tree, and then select AI Application > People Counting >
People Counting.
Step 3
Click Add Rule, select In Area No., and then click
to enable the function.
Step 4
Draw a detection area.
●
Click to draw the detection area.
Содержание DHI-IVSS7008
Страница 1: ...IVSS User s Manual ZHEJIANG DAHUA VISION TECHNOLOGY CO LTD V5 0 0 ...
Страница 50: ...User s Manual 30 common grounded with the Device ...
Страница 142: ...User s Manual 122 Figure 6 82 Search result Other Operations Click one displayed panel and the icons are displayed ...
Страница 158: ...User s Manual 138 Figure 6 103 Human Figure 6 104 Vehicle Figure 6 105 Non motor vehicle ...
Страница 335: ...User s Manual 315 Figure 8 106 Enter email address Figure 8 107 Scan QR code Step 4 Reset the password ...
Страница 368: ...User s Manual 348 Figure 11 2 Unlock the client ...
Страница 381: ...User s Manual ...