5
PRO-VISION rev.04
PRO-VISION
1.3. Controller’s Overview
The PRO-VISION is an electronic device used
for environmental control in livestock build-
ings. It combines sidewall, natural and tunnel
ventilation into one powerful system.
OUTPUTS —
The PRO-VISION can control
up to 128 relays located in external relay
panels. These relays can be used to control
the following outputs:
32 heaters;
16 hi-fire heaters;
5 lateral fans;
20 tunnel fans;
1 stir fan;
6 cooling outputs;
2 tunnel inlets;
2 natural ventilation curtains;
1 sidewall vent;
1 attic vent;
8 time clocks;
2 light outputs (0-10V);
8 water line flushing outputs;
1 egg room heater;
1 egg room cooling output;
1 egg room humidity output;
1 alarm output;
1 backup relay;
4 feeder cut-off relays.
BUILT-IN INPUTS:
32 inside temperature sensors (8 basic
temperature inputs & up to 24 additional
inputs with the expansion cards);
1 outside temperature sensor;
1 relative humidity sensor;
1 static pressure sensor;
1 NH
3
sensor;
1 wind speed sensor;
4 feeder monitoring inputs;
2 water meters.
Refer to the end of this manual to con-
nect the sensors and loads.
INTRODUCTION
1.
Precautions
1.1.
WARNING: Read and save these in-
structions!
Safety may be jeopardized if the equipment is
used in a manner not specified by the manu-
facturer. Carefully read and keep the following
instructions for future reference.
We strongly recommend installing supplemen-
tary natural ventilation as well as a backup
thermostat on at least one cooling stage.
Although fuses at the input and outputs of
the controller protect its circuits in case of
an overload or over-voltage, we recommend
installing an additional protection device on
the controller’s supply circuit.
The room temperature where the controller
is located must always remain between 32°F
and 104°F (0°C to 40°C). Indoor use only!
To avoid exposing the controller to harmful
gases or excessive humidity, it is preferable
to install it in a corridor.
If the equipment is used in a manner not
specified by the manufacturer, the protec-
tion provided by the equipment may be
impaired.
Do not spray water on the controller! In
order to clean the control, wipe it with a
damp cloth.
Before servicing or cleaning unit, switch
power off at service panel and lock the
switch disconnecting means to prevent
power from being switched accidentally.
When the service disconnecting means
cannot be locked, securely fasten a
prominent warning device, such as a
tag, to the service panel.
Symbols of the Manual
1.2.
Warning. Read the following text
carefully; it contains important
information which, if ignored, may
cause the controller to operate
improperly.
High Voltage. Hazard of electrical
shock. Read the message and follow
the instructions carefully.
Pay attention. The following text
contains very useful information.
Press on the proper menu selector.
Press the “Main Menu” push-button.
Both direct and alternating current
(AC/DC).
Direct current (DC).
Alternating current (AC).
Earth Ground Terminal
Primarily used for functional earth
terminals which are generally asso-
ciated with test and measurement
circuits. These terminals are not
for safety earthing purposes but
provide an earth reference point.
For Customer Use:
Enter below the serial
number located on the side of the alarm
system and keep this information for future
reference.
Model: PRO-VISION
Serial number:
Date installed: