4.5.2. Selecting the Attic Sensor
If a temperature sensor is present in the attic,
please select which input number the attic
sensor uses.
Select:
1.
Main menu
* Inlets / Vents
* * Attic Sensors
* This menu is accessible if at least 1 inlet is enabled
in the Set-up menu (see section 4.4). A password may
also be required to access it (see section 4.2.1).
* * This tab is accessible if the attic sensor input is
enabled in the Set-up menu (see section 4.4).
Attic Sensor
To modify use
1
2
3
4
5
6
7
8
---
---
---
---
---
---
---
9
10
11
12
13
14
15
16
---
---
---
---
---
---
---
---
17
18
19
20
21
22
23
24
---
---
---
---
---
---
---
---
25
26
27
28
29
30
31
32
---
---
---
---
---
---
---
---
Use the +/- buttons to put a check mark
2.
in the box of the temperature sensor located
in the attic.
Egg Room Sensors
4.5.3.
If it is used in a breeder facility, the control-
ler automatically enables an egg room and
controls up to 3 outputs in this room (heater,
cooling & humidity outputs). Each of these
outputs operates according to a specific
temperature sensor. Please refer to chapter
11 of this manual to specify which sensor is
used in the egg room.
Main Breaker Sensor
4.5.4.
A temperature sensor can be used to moni-
tor the temperature of the main breaker. The
controller will set off an alarm whenever the
reading of this temperature input gets too
high. Refer to the Set-up menu in section
4.4 to select the temperature sensors used
for this purpose (if applicable).
4.6. Calibrating the Inputs
This section shows how to calibrate the reading
of the sensor inputs in order to obtain accurate
and uniform readings from all sensors. It also
shows how to calibrate the flow rate of the
water meters.
Select:
1.
Main menu
* Set-up
Sensor Calib.
* A complete-access password may be required to
access this menu (see sec. 4.2.1).
A table showing the calibration values of each
sensor input is displayed:
Sensor calibration
Temperature sensor 1
Temperature sensor 2
Temperature sensor 3
Outside temperature sensor
Static pressure sensor
Relative humidity sensor
Water meter 1
Water meter 2
Min ammonia value
Max ammonia value
0.0
0.0
0.0
0.0
0.00
0.0
1gal/p
1gal/p
0 ppm
1000 ppm
To modify use
-
If required, calibrate the reading of the
2.
sensors. Note that the calibration settings are
common to all programs of the controller.
Use the +/- key to enter a negative
offset.
Temperature (indoor & outdoor) —
The reading
of the inside and outside temperature sensors
can be adjusted of ±10 °F (±5.6 °C).
Static pressure sensor —
The reading of the
static pressure sensor can be adjusted of
±0.10 ”WC (±25 Pa). *
This parameter is acces-
sible if the static pressure sensor is enabled in the
Set-up menu (see section 4.4).
Relative humidity sensor —
The reading of
humidity sensor can be adjusted of ±10%.
*
This parameter is accessible if the RH sensor is
enabled in the Set-up menu (see section 4.4).
Water meter calibration —
Specify the flow
rate of each water meter. It ranges from 1 to
100 gallons (or liters) per pulse. *
This param-
eter is accessible if a water meter is enabled in the
Set-up menu (see section 4.4).
Min/max ammonia values—
In order to use
the ammonia sensor, you must specify the
minimum and maximum ammonia levels that
can be detected by the sensor (in ppm). *
This
parameter is accessible if the ammonia sensor is
enabled in the Set-up menu (see section 4.4).
4.7. Relays
Relay Assignment
4.7.1.
The controller activates the loads by means
of external relay panels. In all, it can control
up to 128 relays. This section shows how to
specify the function of each relay. Please refer
to the wiring diagram enclosed with your relay
panel to connect the loads and to assign the
ID numbers of the panels.
A worksheet is available at the end of
this manual to write down the function
of each relay.
Select:
1.
Main menu
* Set-up
Relay Assign
* A complete-access password may be required to
access this menu (see sec. 4.2.1).
The function of each relay is diplayed.
Relay Assignment
Select an item and press
1
2
3
4
5
6
7
8
Fan 1 Fan 2 Fan 2 Fan 3 Fan 4 Tun 1 Tun 2 Tun 3
9
10
11
12
13
14
15
16
Heat HiFi1 Heat2 HiFi2 Heat3 HiFi3 Cool 1 Cool 2
17
18
19
20
21
22
23
24
Cool 3 Cool 4 Stir SV-O SV-C AV-O AV-C TN-O
25
26
27
28
29
30
31
32
TN-C Clk 1 Clk 2 Clk 3
-
-
-
-
Use the arrow keys to select the desired
2.
relay number and then press
“Enter”
to change
its function. A table showing all possible
functions prompts on screen.
Relay 1 Assignment
Htr
HiFi
Fan
Tun Feed Cool
Clk
Flu
Stir Light Bckup SW-O
SW-C TN-O TN-C AV-O AV-C Eg.Cool
Eg.Htr Eg.RH
Off
Use the arrow keys to select the type of
output being controlled by the relay and then
press
“Enter”
.
Содержание PRO-VISION
Страница 54: ...PRO VISION NOTES NOTAS...
Страница 55: ...PRO VISION NOTES NOTAS...