33
PRO-VISION rev.04
PRO-VISION
Select:
1.
Main menu
* On / Off Settings
**Egg room
* A password may be required to access this menu
(see section 4.2.1).
* * This menu is accessible if the breeder mode is
enabled in the Set-up menu (see section 4.4).
Egg room
To modify use
Items Start
Stop Sensor
Heat
74.0°F 75.0°F Sensor 1
Cool
74.0°F 75.0°F Sensor 1
RH
74.0°F 75.0°F
Set the following parameters:
2.
Heat On/Off temperatures —
Set the tem-
perature below which the egg room heating
output starts and above which it stops. Note
that the
“Off Temperature”
must be greater
than the
“On Temperature”
.
Cool On/Off temperatures —
Set the tempera-
ture at which the egg room cooling output
starts and below which it stops. Note that
the
“Off Temperature”
must be lower than the
“On Temperature”
.
On/Off humidity levels —
Set the relative
humidity level at which the egg room humid-
ity output starts and below which it stops.
Note that the
“Off RH level”
must be lower
that the
“On RH level”.
*
This output is acces-
sible if the RH Sensor is enabled in the Set-up menu
(see section 4.4.).
Sensor —
Select which temperature sensor
is used to control the egg room heating &
cooling outputs. Note that the same sensor
can be used to control both outputs.
11. EGG ROOM OUTPUTS
If it is used in a breeder facility the controller
automatically enables an egg room and con-
trols the ambient temperature and humidity
level of in it with its 3 egg room outputs (egg
room cooling, heating and humidity outputs).
Refer to the Set-up menu in section 4.4 to
select in what type of facility the controller
is located (breeder, broiler or turkey).
When the egg room is used, the PRO-VISION
also keeps a tally of the number of eggs pro-
duced each day (the egg tally includes the
daily count of produced, cracked and floor
eggs as well as the daily average egg weight)
and finally allows setting the time clocks with
a weekly schedule. Refer to section 14.4 to
access the egg count menu and refer to sec-
tion 9.1 to set the egg room time clocks.
Reference Temperature:
All egg room outputs
operate according to the egg room tempera-
ture. Refer to section 4.5 to select which tem-
perature sensors are located in this room.
Relative Humidity in the Egg Room
: If the
egg room is enabled and the controller uses a
relative humidity (RH) sensor, the RH sensor
must be located inside the egg room.
Egg Room Heating Output:
The controller can
control 1 heating output in the egg room. This
output starts when the egg room temperature
gets lower than its
“On Temperature”
and stops
when the egg room temperature reaches its
“Off Temperature”
.
Heater in the
Egg Room
Output
Status
Egg
room T°
On T°
Off
On
Off T°
Egg Room Cooling Output:
The controller can
control 1 cooling output in the egg room. This
output starts when the egg room temperature
reaches its
“On Temperature”
and stops when
the egg room temperature gets lower than
the its
“Off Temperature”
.
Cooling Output in the
Egg Room
Output
Status
Egg
room T°
Off T°
Off
On
On T°
Egg Room Humidity Output:
The controller
can control 1 relative humidity (RH) output in
the egg room. This output starts when the RH
level in the egg room gets lower than its
“On
RH level”
and stops when the RH level reaches
its
“Off RH level”
.
Humidity Output in the
Egg Room
Output
Status
Egg
room RH
Level
On Level
Off
On
Off Level