30
PRO-VISION rev.04
PRO-VISION
Light Peak Settings
8.2.2.
Select:
1.
Main menu
* Light Programs
** Peaks
* This menu is accessible if the light output is enabled
in the Set-up menu (see section 4.4). A password may
also be required to access it (see sect. 4.2.1).
* * This tab is accessible if the “Use Peak” option
is enabled in section 8.2.1.
Light peak settings
To modify use
-
Adjust
Cycle
Sunrise
Intensity
Enabled
Peak time
Sunset
Cycle 1
0:15 H:M
2min
100%
No
1min
2min
Set the following parameters:
2.
Adjust —
Select the desired light cycle. All
parameters below are related to the chosen
cycle.
Enabled —
Select
“Yes”
to use light peaks
during the selected light cycle.
Cycle —
Select how much time is required
to perform a light peak cycle (see previous
graph). Note that the
“Cycle Time”
must be
even or longer than the
“Peak time + Peak Sun-
rise + Peak Sunset”
.
Peak Time —
Select during how much time
the light peak intensity must be maintained
(from 0 to 59 minutes).
Sunrise / Sunset —
Select the duration of
the peak sunrise and sunset (see previous
graph). These parameters range from 1 to
60 minutes.
Intensity —
Set the intensity of light peaks to
the desired value. It ranges from the regular
light intensity (as defined in previous section)
to 100%.
9. TIME CLOCKS
Clocks in a Broiler or
9.1.
Turkey Facility
When it is used in a broiler or in a turkey facil-
ity, the controller can control 8 time clocks
with 12 timer cycles each. These outputs
are used to activate different kind of devices
using the real-time clock.
A time clock starts when the
“On Time”
of a
time clock cycle is reached; the output either
stops after a certain run time or at a certain
time of day. The following diagrams show
both possibilities:
Time
Time
Output
Status
Cycle
Cycle
Output
Status
On
Start Time
(e.g. 8h30AM)
Start Time
(e.g. 8h30AM)
Time Clock:
Start/Run Mode
Time Clock:
Start/Stop Mode
Run Time
(e.g. 30m:15s)
Stop Time
(e.g. 9h00AM)
On
Off
Off
Note that the
“Start/Run”
mode allows stop-
ping the outputs with a little more precision
since it allows stopping them by the seconds
(contrarily to the
“Start/Stop”
mode which
allows stopping them by the minutes). Refer
to the Set-up menu in section 4.4 to choose
the desired operating mode of the time clocks
(
“Start/Stop”
or
“Start/Run”
).
1. Select:
Main menu
* On / Off Settings
* *Time clock
*A password may be required to access this menu
(see section 4.2.1).
* * This menu is accessible if at least 1 time clock is
enabled in the Set-up menu (see section 4.4).
Note that the time clock menu will appear as
shown below only if the
“Broiler”
or
“Turkey”
facility is enabled in the Set-up menu (see
section 4.4).
Cycle
Start
Stop
Run
1
11:00A
11:15A 00:15:00
2
2:00P
2:15A 00:15:00
3
4:00P
4:15P 00:15:00
4
6:00P
6:15P 00:15:00
5
12:00A
12:00A 00:15:00
6
12:00A
12:00A 00:15:00
7
12:00A
12:00A 00:15:00
8
12:00A
12:00A 00:15:00
9
12:00A
12:00A 00:15:00
10
12:00A
12:00A 00:15:00
11
12:00A
12:00A 00:15:00
12
12:00A
12:00A 00:15:00
Display Clock 2
To Modify Press
-
Select the desired time clock output.
2.
Set the following parameters:
3.
Start Time —
Set the time at which each
cycle starts. If 12 cycles are not required, set
the
“Start & Stop Times”
of the unused cycles
to the same value or set the
“Run Time”
to
0:00:00. NB. Use the
“AM/PM”
key to change
the time indicator (if required).
Stop or Run Time —
The cycles can either
stop at a specific time of day or after a certain
run time. Set the time at which each cycle
ends. NB. Use the
“AM/PM”
key to change the
time indicator (if required). *
Refer to section 4.4
to choose how the time clocks must stop.
Содержание PRO-VISION
Страница 54: ...PRO VISION NOTES NOTAS...
Страница 55: ...PRO VISION NOTES NOTAS...