27
PRO-VISION rev.04
PRO-VISION
Operating Time Range:
The user can specify
a range of time over which the cooling out-
puts can run. This allows deactivating them
at night for instance.
Reference Temperature:
Each cooling output
operates according to the average tempera-
ture reading of its respective group of sen-
sors. Refer to section 4.5 to assign these
sensors. The operating temperatures of the
cooling outputs are also related to the tem-
perature set point. This means that if the
temperature set point changes the ON & OFF
temperatures of these outputs are adjusted
consequently.
Cooling Output in the Egg Room:
The con-
troller can control a supplementary cooling
output in the egg room. This output operates
differently from the cooling outputs that are
used in the rest of the house. Refer to chapter
11 of this manual to get information about the
egg room cooling output.
Select:
1.
Main menu
* On / Off Settings
* A password may be required to access this menu
(see section 4.2.1).
Cool 1
Settings
On/Off Settings
...
Cool 1
Cool 2
Cool 3
Cool 4
Cool 5
Cool 6
...
On Off
Mode Fan shutoff
Items
To modify use
-
Set Point : 75.0
...
85.0
84.5
85.0 84.5 Cooling
85.0 84.5 Cooling
85.0 84.5 Cooling
85.0 84.5 Cooling
85.0 84.5 Cooling
...
Use the arrow keys to scroll down and select
2.
the desired cooling output.
* These outputs are
available if they have previously been enabled in the
Set-up menu (see section 4.4).
Set the temperature at which each cool-
3.
ing output starts running in timer mode (
“On
Temperature”
) and the temperature below
which the output stops (
“Off Temperature”
).
Note that the temperature at which the output
starts must be greater than the temperature
at which it stops.
Select the
4.
“Settings”
tab that is associated
with the chosen cooling output with the menu
selectors.
Set the following parameters separately
5.
for each cooling output in use:
Cool 1 Settings
Max Run T°
Cycle
Stop at
On Time
Start at
95.0
0:30 M:S
9:00 pm
1:00 M:S
6:00 am
Max Run T° —
Set the temperature at which
the cooling output runs continuously (i.e.,
the
“On Time”
portion of the timer is equal to
the
“Cycle Time”
). Note that this parameter
value must be greater than the temperature
at which the output starts.
On Time —
Set the
“On Time”
of the regular
cooling timer.
Cycle —
Set the
“Cycle Time”
of the cooling
timer. Note that the
“Cycle Time”
must be
longer than the
“On Time”
.
Start At / Stop At —
Specify the period of time
over which the cooling outputs can run.
6.7. Stir Fans
The controller has 1 stir fan output that can
either be used in minimum ventilation or
when the room temperature gets lower than
a user-defined limit. Refer to the Set-up menu
to enable the desired operating mode of this
output (section 4.4).
Stir Fans in Minimum Ventilation:
When they
are used in minimum ventilation the stir fans
only run during the
“Off Time”
portion of the
minimum ventilation cycles. This ensures
good air circulation when the exhaust fans
are not running.
Stir Fans as a Function of Temperature:
When
they operate as a function of temperature,
the stir fans run in timer mode when the av-
erage temperature is lower than the output’s
“On Temperature”
and stop when the room
temperature rises and reaches the output’s
“Off Temperature”
.
Stir Fan as a
Function of
Temperature
Stir Fan
Timer
Room T°
On T°
Off
On
Off T°
Reference Temperature:
Operating tempera-
tures of the stir fan output are related to the
temperature set point. This means that if the
set point changes, the ON and OFF Tempera-
tures are adjusted consequently.
ON
OFF
Output
Status
Stir Fan Timer
Time
ON
Time
Cycle
Time