16
PRO-VISION rev.04
PRO-VISION
SET POINTS
5.
5.1. Temperature & RH Set
Points
Select:
1.
Main menu
* Set Point
* A password may be required to access this menu
(see section 4.2.1).
The current temperature & relative humid-
ity (RH) set points are displayed along with
a graph of the temperature set point ramp.
Refer to section 5.2 for further information
about this ramp.
Set Point
Non brood
75.0
35.0
Ramping
Temperature
90.0
84.4
81.6
78.8
76.0
73.2
70.4
67.6
64.8
62.0
1
5
10
14 19
24
28
33
38 42 47 Age
Set Point
Ramping
RH Set Point
65
To modify use
-
Set the following parameters:
2.
Set Point —
The
Set Point
is the target tempera-
ture in the room. The operating temperatures
of most outputs are based on this value,
which means that if the set point changes,
the start & stop temperatures of the outputs
are adjusted accordingly. Set the temperature
set point to the desired value. Also note that
if the set point ramp is enabled, the controller
automatically defines this value as a function
of the animal age (see section 5.2). *
This
parameter is common to all programs.
Non brood —
Set the target temperature used
in the non-brood zones. *
Refer to section 4.8 for
further information about non brood zones.
RH Set Point —
The relative humidity (RH) set
point is the target level of relative humidity
in the room. It is only used if the controller
is used in a broiler or turkey facility. If the
humidity level in the room gets higher than
this set point, the controller can enable differ-
ent compensation functions to lower it down
(see chapter 12). Set the relative humidity set
point to the desired value. *
This parameter is
accessible if the controller is used in a broiler or
turkey facility. Refer to the Set-up menu to select the
type of facility (breeder, broiler or turkey).
5.2. Set Point Ramp
The controller can automatically adjust the
temperature set point over time with a ramp.
The set point ramp is composed of 12 steps
and each step associates a temperature set
point with an animal age. Once the ramp is
enabled, the controller changes the tempera-
ture set point every hour in a linear fashion
between consecutive steps of the ramp.
When it reaches the last step, the controller
keeps using the last temperature set point
until the end of the flock.
Temperature
90.0
87.2
84.4
81.6
78.8
76.0
73.2
70.4
67.6
64.8
62.0
1 5 10 14 19 24 28 33 38 42 47 Age
Temperature
Set Point Ramp
Select:
1.
Main menu
* Set Point
Ramping
* A password may be required to access this menu
(see section 4.2.1).
Ramping Status: OFF
To modify use
-
Age SetPoint
1
90.0°F
7
85.0°F
10
80.0°F
15
78.0°F
21
72.0°F
25
70.0°F
28
68.0°F
32
66.0°F
36
64.0°F
40
62.0°F
46
62.0°F
47
62.0°F
Set the following parameters.
2.
* The param-
eters below are common to all programs.
Ramping Status —
This is the status of the
set point ramp. Select
“On”
to enable it or
select
“Off”
to disable it.
Age —
Set the age at which each step starts.
This parameter ranges from -5 to 450 days
(negative values are used to prepare the
house before letting the animals in).
Temperature —
Assign a temperature set
point with each step of the ramp. If you don’t
need 12 different steps, repeat the last tem-
perature for each unnecessary step.
Содержание PRO-VISION