39
PRO-VISION rev.04
PRO-VISION
MONITORING FUNC-
14.
TIONS
14.1.
Current Conditions
Current Condition Screen
14.1.1.
Saver
The current condition screen saver
gives a quick overview of the actual
conditions in the barn. This screen is
automatically displayed after 5 min-
utes of inactivity and shows the basic
conditions in the room: temperature,
static pressure level, humidity level
and light intensity.
Main menu, press any key
77.5
75 %
0.06
100 %
14.1.2. Current Input/Output Status
Select:
1.
Main menu
Current conditions
The controller displays the current reading of
each input along with other useful information
such as temperature and heater run times.
It is also possible to refine this screen display
by removing some pieces of information
from it, such as the individual reading of the
temperature sensors and the run time of the
heaters. Refer to the Set-up menu in section
4.4 to modify the information displayed on
the current condition screen.
Output
Status
Current Conditions
Temperature Sensors
Today's heater run time
Min Temp.
Avr temp.
Max Temp.
Age
75.2°F
77.5°F
80.0°F
5
Out. Temp.
Humidity
S.P.
Water 1
78.0°F
75%
0.06"WC
7 gal
Water 2
Ammonia
Wind spd
3 gal
0ppm
0ft/min
Hi
Hi
Hi
Hi
Hi
Hi
75.3
75.1
74.7
74.9
75.0
75.6
74.4
75.0
0:00
0:00
0:00
0:00
0:00
0:00
0:00
0:00
0:00
0:00
0:00
0:00
Display
Meaning
Heat
1-32 ( ) Heater #x is active.
HiFi
1-16 ( ) Hi Fire Heater #x is active.
Fan
1-5 ( ) Fan #x is active.
Tun
1-20 ( ) Tunnel fan #x is active.
Stir
( ) Stir fan is active.
Cool
1-6 ( ) Cooling output #x is active.
Clk
1-8 ( ) Time clock #x is active.
Feed
1-4 ( ) Feeder #x run time monitoring re-
lay is closed (no run time alarm)
Wtr
1-8 ( ) Water flush output #x is active.
SV
/ ( ) The sidewall vent is closing/
opening
AV
/ ( ) The attic vent is closing/opening.
Tun
/ ( ) Tunnel inlet 1 is closing/opening.
Tun2
/ ( ) Tunnel inlet 2 is closing/opening.
Nat
/ ( ) Natural curtain 1 is closing/opening
Nat2
/ ( ) Natural curtain 2 is closing/opening
Htr
( ) Egg room heating output
Cool
( ) Egg room cooling output
RH
( ) Egg room humidity output
Select the
2.
“Output Status”
tab with the
menu selectors. A table containing the status
of each output is displayed.
Heat
HiFi
Fan
Tun
Stir
Cool
Clk
Feed
Wtr
SV
Tun
Output Status
Below is a table showing the meaning of all