32
PRO-VISION rev.04
PRO-VISION
10. WATER LINE FLUSH
The controller can flush 8 water line outputs
in turn and can repeat the flushing process up
to 4 times a day. Note that 2 water lines can
be connected to each water line output.
Water Flush Cycle:
When a water flush cycle
starts, the controller flushes all water line
outputs in turn : after having flushed a water
line output, it waits for a certain delay before
flushing the lines of the next output. In all, up
to 4 cycles can be performed each day.
Water Flush Program:
A water flush program
is the combination of all water flush cycles
that are performed in a day. The water flush
parameters must be associated with a par-
ticular program which starts at a specific
age. Using multiple programs is useful to
adapt the frequency and the duration of the
flushing cycles as the birds are growing. Up
to 5 different water flush programs can be
defined.
Select:
1.
Main menu
* On / Off Settings
* * Water Flush
*A password may be required to access this menu
(see section 4.2.1).
* * This menu is accessible if at least 1 water flush
line output is enabled in the Set-up menu (see sec-
tion 4.4).
Set the following parameters:
2.
Water Flush
To modify use
-
Start Age
Interval
Start 1
Start 3
Display
Skip day
Duration
# of cycles
Start 2
Start 4
1
0:10 H:M
12:00 am
12:00 am
Program1
No
0:10 H:M
4
12:00 am
12:00 am
Mon Tue Wed Thu Fri Sat Sun
or
Water Flush
To modify use
-
Start Age
Interval
Start 1
Start 3
Display
Skip day
Duration
# of cycles
Start 2
Start 4
1
0:10 H:M
12:00 am
12:00 am
Program1
2
0:10 H:M
4
12:00 am
12:00 am
Start
Mon
Duration
Interval
Duration
Interval
Duration
Interval
Duration
Output #1
starts
flushing
Output #2
starts
flushing
Output #3
starts
flushing
Output #4
starts
flushing
Cycle #1
Cycle #2
Cycle #3
Cycle #4
1 Program
1 Cycle
Water Flush Cycles & Programs
Display —
Select the desired water flush pro-
gram (program 1-5). All parameters below are
related to the chosen water flush program.
Skip day —
Water flush can either be per-
formed accroding to a weekly schedule
(7 days) or they can be stopped at regular
intervals without considering the day of the
week. Select
“No”
to use the weekly schedule
or select the number of days to be skipped
after each operating day (1-5 days).
Start Day —
Select on what day of the
week the water flush schedule starts. *
This
parameter is displayed if the “Skip Day” option is
enabled above.
Start Age —
Select the age at which the
selected water flush program starts.
Day of the Week —
Select on which days of
the week the water flush program must be
performed. *
This parameter is accessible if the
“Skip Day” option is set to “No”.
Duration —
Specify the amount of time re-
quired to flush one (1) water line output. The
duration of water flushes is the same for all
water line outputs.
Interval —
After having flushed a water line
output, the controller waits for this time delay
before flushing the water lines of the next
output. Note that this delay is common to all
water line outputs.
Number of cycles —
Select the number of
daily flush cycles that must be performed
in the course of the selected program (1 to
4 cycles per day).
Start 1-4 —
Select the start time of each
water flush cycle. NB. Use the
“AM/PM “
key
to change the time indicator (if required).