CTC EcoZenith i350
11.10 DHW tank
DHW program
Settings menus for the Economy, Normal and
Comfortprograms. Refer to the DHW Program Settings
section.
Start/stop diff. upper °C
5 (3—10)
The temperature difference between charge start and
stop.
Max. time DHW
30 (10—150)
This is the maximum time (in minutes) that the heat
pump charges the hot water tank, if this is needed for
the heating circuit.
Charge pump %
50 (25—100)
Setting for charge pump (G11) speed during hot water
charging. Only applies if the heat pump is not the sole
heater.
Smart Low price °C
10 (1—30)
Read more in the “Smartgrid” section.
Smart Overcapacity °C
10 (1—30)
Read more in the “Smartgrid” section.
Min. RPS DHW charging
50 (50—100)
Lowest compressor speed during hot water charging.
When the heat pump switches from heating to hot
water, this RPS is used for hot water.
DHW circulation (accessory)
The settings for hot water circulation require the
installation of an expansion card accessory (A3).
Run time DHW circ.
4 (1 to 90)
The length of time (minutes) that domestic hot water
circulation should take place during each period. Applies
if DHW circulation has been defined in the Installer/
Define system menu.
Time DHW circ.
15 (5 to 90)
The time (minutes) during which domestic hot water
circulation takes place. DHW circulation must have been
defined in the Installer/Define system menu.
Timer DHW circulation
On/Off/Day by day
This menu displays the scheduled weekday periods
when the DHW circulation pump is to run. This schedule
is repeated every week.
Dansk
Nederlands
Čeština
Eesti
Polski
Slovenščina
Svenska
Norsk
English
Deutsch
Suomi
Française
DHW tank
Settings language
Settings language
DHW program
Start/stop diff. upper °C
5
Max. time DHW
30
Charge pump %
50
Smart low price ºC
10
Smart overcapacity
10
Min. RPS DHW charging
Time DHW-circ.
4
Timer DHW-circulation
15
Timer VV-cirk
Add heat DHW
No
Time extra DHW Remote cont
0.0
EcoAir 500M
Dansk
Nederlands
Čeština
Eesti
Polski
Slovenščina
Svenska
Norsk
English
Deutsch
Suomi
Française
06 - 09
18 - 21
07 - 09
20 - 23
06 - 09
10 - 21
06 - --
-- - 21
06 - --
-- - 21
10 - 12
20 - 23
10 - 12
20 - 23
Timer DHW circulation
Settings language
Settings language
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
Sunday
The time on the left must be lower than the time on the right for
the interval to be valid.
Содержание EcoZenith i350 H
Страница 4: ...4 CTC EcoZenith i350...
Страница 27: ...27 CTC EcoZenith i350...
Страница 29: ...29 CTC EcoZenith i350...
Страница 30: ...30 CTC EcoZenith i350 X2 6 4 Wiring diagram CTC EcoZenith i350 3x400V...
Страница 32: ...32 CTC EcoZenith i350 X2 6 5 Wiring diagram CTC EcoZenith i350 1x230V...
Страница 34: ...34 CTC EcoZenith i350 X2 6 6 Wiring diagram CTC EcoZenith i350 3x230V...
Страница 105: ...105 CTC EcoZenith i350...
Страница 115: ......
Страница 116: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 205 22 2 2017 11 14...