CTC EcoZenith i350
13. Factory settings
Designation
Factory value Min value Max value Alternative
Set
Instal.
Heating circuit
Max primary flow °C
55
30
70
Min primary flow °C
Off
15
65
Off
Heating, mode
Auto
Auto On
Off
Heating mode, ext
-
Auto On
Off
Heat off, outside °C
18
10
30
Heating off, time
120
30
240
Inclination °C
50
25
85
Adjustment °C
0
-20
20
Night reduction off °C
5
-40
40
Room temp reduced °C
-2
-40
0
Primary flow reduced °C
-3
-40
0
Alarm, low room temp °C
5
-40
40
Smart low price. °C
1
0
5
Off
Smart over capacity °C
2
0
5
Off
Max time heating
40
10
120
Charge pump %
90
25
100
Drying period mode
Off
1
3
Off
Drying period temp °C
25
25
55
Heat pump
Compressor
Blocked
Permitted
Brine pump on (CTC EcoPart)
Auto
10d
On
Stop at outdoor temp °C (EcoAir)
-22
-22
10
Tariff HP
-
Off
On
Smart blocking HP
-
Off
On
Start at degree minute
-60
-900
-30
HS<->DHW time (sec)
120
30
240
Max RPS *(EcoAir 500M)
90
50
100
Max RPS silent mode *(EcoAir 500M)
50
49
100
Max RPS warm temp *(EcoAir 500M)
50
50
100
Cold temp limit *(EcoAir 500M)
0
-15
0
Warm temp limit *(EcoAir 500M)
20
0
20
Immersion heater
Max el. heater kW
9.1
0
11.9
Max el. heater DHW kW
9.1
0
11.9
Start at degree minute
-500
-900
-30
Diff step, degree minute
-50
-300
-20
Main fuse A
20
10
90
Conv. factor curr. sensors
1
1
10
Input voltage
3x400 V
1x230
3x230
Tariff el.
-
Off
On
Smart block immersion
-
Off
On
Содержание EcoZenith i350 H
Страница 4: ...4 CTC EcoZenith i350...
Страница 27: ...27 CTC EcoZenith i350...
Страница 29: ...29 CTC EcoZenith i350...
Страница 30: ...30 CTC EcoZenith i350 X2 6 4 Wiring diagram CTC EcoZenith i350 3x400V...
Страница 32: ...32 CTC EcoZenith i350 X2 6 5 Wiring diagram CTC EcoZenith i350 1x230V...
Страница 34: ...34 CTC EcoZenith i350 X2 6 6 Wiring diagram CTC EcoZenith i350 3x230V...
Страница 105: ...105 CTC EcoZenith i350...
Страница 115: ......
Страница 116: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 205 22 2 2017 11 14...