![CTC Union EcoZenith i350 H Скачать руководство пользователя страница 49](http://html1.mh-extra.com/html/ctc-union/ecozenith-i350-h/ecozenith-i350-h_installation-and-maintenance-manual_2693231049.webp)
49
CTC EcoZenith i350
i
If a value is set too low, this may prevent the desired room temperature from
being reached. If this occurs, you should adjust the heating curve as required in
accordance with the above.
When the basic values have been set more or less correctly, the curve can
be finely adjusted directly from Room temp. on the home menu screen.
Decrease the Adjustment value by a couple of degrees.
Wait 24 hours to see if any further adjustment is required.
9.1
Adjusting the heating curve
The method described below can be used to adjust the heating curve
correctly.
Adjustment if it is too cold indoors
• If the outdoor temperature is
lower
than zero degrees:
Increase the Inclination value by a couple of degrees.
Wait 24 hours to see if any further adjustment is required.
• If the outdoor temperature is
higher
than zero degrees:
Increase the Adjustment value by a couple of degrees.
Wait 24 hours to see if any further adjustment is required.
Adjustment if it is too warm indoors
• If the outdoor temperature is
lower
than zero degrees:
Decrease the Inclination value by a couple of degrees.
Wait 24 hours to see if any further adjustment is required.
• If the outdoor temperature is
higher
than zero degrees:
Appropriate default values
During installation you can seldom achieve a precise setting for the heating curve instantly. In this case, the values
given below may provide a good starting point. Radiators with small heat-emission surfaces require a higher primary
flow temperature. You can adjust the gradient (heating curve gradient) for your heating circuit in the Installer/Settings/
Heating circuit menu.
The recommended values are:
Floor heating only
Inclination 35
Low temperature system (well insulated houses)
Inclination 40
Normal temperature system (factory setting)
Inclination 50
High temperature system (older houses, small radiators, poorly insulated) Inclination 60
Содержание EcoZenith i350 H
Страница 4: ...4 CTC EcoZenith i350...
Страница 27: ...27 CTC EcoZenith i350...
Страница 29: ...29 CTC EcoZenith i350...
Страница 30: ...30 CTC EcoZenith i350 X2 6 4 Wiring diagram CTC EcoZenith i350 3x400V...
Страница 32: ...32 CTC EcoZenith i350 X2 6 5 Wiring diagram CTC EcoZenith i350 1x230V...
Страница 34: ...34 CTC EcoZenith i350 X2 6 6 Wiring diagram CTC EcoZenith i350 3x230V...
Страница 105: ...105 CTC EcoZenith i350...
Страница 115: ......
Страница 116: ...Enertech AB P O Box 309 SE 341 26 Ljungby Sweden www ctc se www ctc heating com 162 205 22 2 2017 11 14...